{"product_id":"square-d-hdl26050-50-amp-2-pole-molded-case-circuit-breaker-feed-thru-600v-ac","title":"Square D HDL26050 50 Amp 2-Pole Molded Case Circuit Breaker – Feed-Thru – 600V AC","description":"\u003cp data-start=\"188\" data-end=\"537\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e Square D PowerPact HDL26050 is a 50 Amp, 2-pole molded case circuit breaker designed to provide reliable protection against overloads and short circuits in industrial and commercial electrical systems. Built on the H-Frame PowerPact platform, it ensures safe and consistent operation in distribution panels.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"691\"\u003eIt features thermal-magnetic protection and a feed-thru connection design, making it suitable for flexible installation in various panel configurations.\u003c\/p\u003e\n\u003ch2 data-section-id=\"bkdl9b\" data-start=\"698\" data-end=\"721\"\u003eElectrical Ratings\u003c\/h2\u003e\n\u003cul data-start=\"722\" data-end=\"953\"\u003e\n\u003cli data-section-id=\"1gcquqe\" data-start=\"722\" data-end=\"749\"\u003eCurrent Rating: 50 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1ohb61d\" data-start=\"750\" data-end=\"782\"\u003eVoltage Rating: 600 Volts AC\u003c\/li\u003e\n\u003cli data-section-id=\"1fhp8kg\" data-start=\"783\" data-end=\"812\"\u003ePhase: Single Phase (1PH)\u003c\/li\u003e\n\u003cli data-section-id=\"1dabzbe\" data-start=\"813\" data-end=\"855\"\u003eInterrupting Capacity: 18 kA @ 480V AC\u003c\/li\u003e\n\u003cli data-section-id=\"z1rro\" data-start=\"856\" data-end=\"894\"\u003eBreaking Capacity: 14 kA @ 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"l5qh7g\" data-start=\"895\" data-end=\"929\"\u003eContinuous Current Rating: 80%\u003c\/li\u003e\n\u003cli data-section-id=\"2mq84v\" data-start=\"930\" data-end=\"953\"\u003eFrame Type: H-Frame\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"9auaen\" data-start=\"960\" data-end=\"994\"\u003eBreaker \u0026amp; Protection Features\u003c\/h2\u003e\n\u003cul data-start=\"995\" data-end=\"1364\"\u003e\n\u003cli data-section-id=\"c6w748\" data-start=\"995\" data-end=\"1047\"\u003eBreaker Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"1807sdw\" data-start=\"1048\" data-end=\"1075\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"7btkfp\" data-start=\"1076\" data-end=\"1118\"\u003eTrip Unit Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"18ns0bi\" data-start=\"1119\" data-end=\"1177\"\u003eTrip Functions: Long-Time and Instantaneous protection\u003c\/li\u003e\n\u003cli data-section-id=\"bzbrid\" data-start=\"1178\" data-end=\"1236\"\u003eProtection Type: Overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"lzmd0n\" data-start=\"1237\" data-end=\"1283\"\u003eManual Operation: Push-to-trip test button\u003c\/li\u003e\n\u003cli data-section-id=\"13r00s1\" data-start=\"1284\" data-end=\"1364\"\u003eContact Design: Dual-break rotating contacts for reduced fault current peaks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"c291ko\" data-start=\"1371\" data-end=\"1397\"\u003eMounting \u0026amp; Connection\u003c\/h2\u003e\n\u003cul data-start=\"1398\" data-end=\"1635\"\u003e\n\u003cli data-section-id=\"1gveroo\" data-start=\"1398\" data-end=\"1428\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"iexq10\" data-start=\"1429\" data-end=\"1474\"\u003eElectrical Connection: Line and load lugs\u003c\/li\u003e\n\u003cli data-section-id=\"1c4jum8\" data-start=\"1475\" data-end=\"1523\"\u003eInstallation Type: H-Frame unit mount system\u003c\/li\u003e\n\u003cli data-section-id=\"1wih1uq\" data-start=\"1524\" data-end=\"1572\"\u003eCompatibility: PowerPact H-Frame panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"axvxs0\" data-start=\"1573\" data-end=\"1635\"\u003eReverse Feed Compatible: Yes (typical for H-Frame designs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"5uyczf\" data-start=\"1642\" data-end=\"1667\"\u003eWiring \u0026amp; Termination\u003c\/h2\u003e\n\u003cul data-start=\"1668\" data-end=\"1870\"\u003e\n\u003cli data-section-id=\"aykui1\" data-start=\"1668\" data-end=\"1714\"\u003eTerminal Type: Lugs on line and load sides\u003c\/li\u003e\n\u003cli data-section-id=\"hu4p48\" data-start=\"1715\" data-end=\"1797\"\u003eWire Size Range: Industrial copper\/aluminum conductors (application dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"fowgw6\" data-start=\"1798\" data-end=\"1870\"\u003eWiring Style: Feed-through configuration for simplified installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"fig7r2\" data-start=\"1877\" data-end=\"1905\"\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1906\" data-end=\"2045\"\u003e\n\u003cli data-section-id=\"233q0q\" data-start=\"1906\" data-end=\"1944\"\u003eCompact H-Frame molded case design\u003c\/li\u003e\n\u003cli data-section-id=\"1lhhbld\" data-start=\"1945\" data-end=\"2002\"\u003eIndustrial-grade enclosure size for 50A breaker class\u003c\/li\u003e\n\u003cli data-section-id=\"1ngg879\" data-start=\"2003\" data-end=\"2045\"\u003eWeight: Not specified in provided data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"fcx5r4\" data-start=\"2052\" data-end=\"2083\"\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul data-start=\"2084\" data-end=\"2223\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2084\" data-end=\"2097\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1xqik9e\" data-start=\"2098\" data-end=\"2114\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"esspgj\" data-start=\"2115\" data-end=\"2132\"\u003eNOM Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1nx0unc\" data-start=\"2133\" data-end=\"2150\"\u003eIEC Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"n6bouy\" data-start=\"2151\" data-end=\"2164\"\u003eCE Marked\u003c\/li\u003e\n\u003cli data-section-id=\"1ophnt\" data-start=\"2165\" data-end=\"2223\"\u003eDesigned for international industrial safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"r68lcr\" data-start=\"2230\" data-end=\"2254\"\u003eAdditional Features\u003c\/h2\u003e\n\u003cul data-start=\"2255\" data-end=\"2547\"\u003e\n\u003cli data-section-id=\"12gflc\" data-start=\"2255\" data-end=\"2320\"\u003eDual-break rotating contact system reduces peak fault current\u003c\/li\u003e\n\u003cli data-section-id=\"fdewva\" data-start=\"2321\" data-end=\"2366\"\u003eBuilt-in push-to-trip manual test feature\u003c\/li\u003e\n\u003cli data-section-id=\"m9m5rc\" data-start=\"2367\" data-end=\"2422\"\u003eHigh reliability thermal-magnetic protection system\u003c\/li\u003e\n\u003cli data-section-id=\"rgx8oi\" data-start=\"2423\" data-end=\"2483\"\u003eFeed-thru wiring configuration for flexible installation\u003c\/li\u003e\n\u003cli data-section-id=\"yunzb2\" data-start=\"2484\" data-end=\"2547\"\u003eSuitable for industrial and commercial distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"8kd7vi\" data-start=\"2554\" data-end=\"2583\"\u003eManufacturer Information\u003c\/h2\u003e\n\u003cul data-start=\"2584\" data-end=\"2709\"\u003e\n\u003cli data-section-id=\"raqjko\" data-start=\"2584\" data-end=\"2639\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"2640\" data-end=\"2659\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1w7d0dk\" data-start=\"2660\" data-end=\"2689\"\u003eSeries: PowerPact H-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1wf7i3w\" data-start=\"2690\" data-end=\"2709\"\u003eModel: HDL26050\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48535383343353,"sku":"HDL26050","price":558.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HDL26020-All-New-1_1adc19f8-0210-446a-ad42-5f7943023fee.webp?v=1781599386","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-hdl26050-50-amp-2-pole-molded-case-circuit-breaker-feed-thru-600v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}