{"product_id":"square-d-homeline-homt230240-quad-tandem-2-x-2-pole-30a-40a-miniature-circuit-breaker-plug-on-120-240v-ac","title":"Square D Homeline HOMT230240 Quad Tandem 2 x 2-Pole (30A + 40A) Miniature Circuit Breaker – Plug-On – 120\/240V AC","description":"\u003cp data-start=\"220\" data-end=\"536\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e Square D Homeline HOMT230240 is a quad tandem miniature circuit breaker designed for Homeline load centers and CSED devices. It provides two independent 2-pole circuits (30A and 40A) in a compact footprint, allowing additional 240V loads without requiring extra panel space.\u003c\/p\u003e\n\u003cp data-start=\"538\" data-end=\"638\"\u003eIt is commonly used in residential applications, especially for HVAC and mixed-load branch circuits.\u003c\/p\u003e\n\u003ch2 data-section-id=\"bkdl9b\" data-start=\"645\" data-end=\"668\"\u003eElectrical Ratings\u003c\/h2\u003e\n\u003cul data-start=\"669\" data-end=\"967\"\u003e\n\u003cli data-section-id=\"pts895\" data-start=\"669\" data-end=\"732\"\u003eCurrent Rating: 30A + 40A (two independent 2-pole breakers)\u003c\/li\u003e\n\u003cli data-section-id=\"1lggaln\" data-start=\"733\" data-end=\"789\"\u003eNumber of Poles: 4 poles (quad tandem configuration)\u003c\/li\u003e\n\u003cli data-section-id=\"1fkj6p9\" data-start=\"790\" data-end=\"826\"\u003eVoltage Rating: 120\/240 Volts AC\u003c\/li\u003e\n\u003cli data-section-id=\"12hex3y\" data-start=\"827\" data-end=\"875\"\u003eInterrupting Capacity: 10 kAIC @ 120\/240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"184qqvg\" data-start=\"876\" data-end=\"888\"\u003ePhase: 1\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"889\" data-end=\"912\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1ck4ace\" data-start=\"913\" data-end=\"967\"\u003eApplication: Residential branch circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"9auaen\" data-start=\"974\" data-end=\"1008\"\u003eBreaker \u0026amp; Protection Features\u003c\/h2\u003e\n\u003cul data-start=\"1009\" data-end=\"1345\"\u003e\n\u003cli data-section-id=\"q7gmpb\" data-start=\"1009\" data-end=\"1054\"\u003eBreaker Type: Quad Tandem Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"trkker\" data-start=\"1055\" data-end=\"1092\"\u003eTrip Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"5ed487\" data-start=\"1093\" data-end=\"1119\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"8xv0vx\" data-start=\"1120\" data-end=\"1167\"\u003eTrip Functions: Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli data-section-id=\"1c17alg\" data-start=\"1168\" data-end=\"1197\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"1co9ny5\" data-start=\"1198\" data-end=\"1251\"\u003eProtection: Overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1131xe7\" data-start=\"1252\" data-end=\"1272\"\u003eCommon Trip: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"y5kgri\" data-start=\"1273\" data-end=\"1345\"\u003eHACR Rated: Yes (Heating, Air Conditioning, Refrigeration equipment)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"c291ko\" data-start=\"1352\" data-end=\"1378\"\u003eMounting \u0026amp; Connection\u003c\/h2\u003e\n\u003cul data-start=\"1379\" data-end=\"1612\"\u003e\n\u003cli data-section-id=\"1kkh616\" data-start=\"1379\" data-end=\"1406\"\u003eMounting Style: Plug-On\u003c\/li\u003e\n\u003cli data-section-id=\"wnyd6x\" data-start=\"1407\" data-end=\"1475\"\u003eConnection Type: Plug-in to Homeline load centers \/ CSED devices\u003c\/li\u003e\n\u003cli data-section-id=\"ebtjh2\" data-start=\"1476\" data-end=\"1503\"\u003eTerminal Type: Box lugs\u003c\/li\u003e\n\u003cli data-section-id=\"s5zbio\" data-start=\"1504\" data-end=\"1559\"\u003ePanel Compatibility: Square D Homeline load centers\u003c\/li\u003e\n\u003cli data-section-id=\"uyih7i\" data-start=\"1560\" data-end=\"1612\"\u003eApplication Fit: Residential distribution panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"5uyczf\" data-start=\"1619\" data-end=\"1644\"\u003eWiring \u0026amp; Termination\u003c\/h2\u003e\n\u003cul data-start=\"1645\" data-end=\"1830\"\u003e\n\u003cli data-section-id=\"vocoz1\" data-start=\"1645\" data-end=\"1732\"\u003eWire Range:\n\u003cul data-start=\"1663\" data-end=\"1732\"\u003e\n\u003cli data-section-id=\"bl2nvt\" data-start=\"1663\" data-end=\"1696\"\u003e30A circuit: 14–8 AWG (Cu\/Al)\u003c\/li\u003e\n\u003cli data-section-id=\"tdex0g\" data-start=\"1699\" data-end=\"1732\"\u003e40A circuit: 14–6 AWG (Cu\/Al)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"v08att\" data-start=\"1733\" data-end=\"1761\"\u003eMaximum Wire Size: 6 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1j655zw\" data-start=\"1762\" data-end=\"1791\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1n63480\" data-start=\"1792\" data-end=\"1830\"\u003eTerminal Type: Box lug connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"tjs37w\" data-start=\"1837\" data-end=\"1874\"\u003ePhysical \u0026amp; Construction Features\u003c\/h2\u003e\n\u003cul data-start=\"1875\" data-end=\"2101\"\u003e\n\u003cli data-section-id=\"1oe886a\" data-start=\"1875\" data-end=\"1927\"\u003eConfiguration: Quad tandem (2 × 2-pole breakers)\u003c\/li\u003e\n\u003cli data-section-id=\"1md2d82\" data-start=\"1928\" data-end=\"1973\"\u003eDesign: Compact space-saving breaker body\u003c\/li\u003e\n\u003cli data-section-id=\"1v7q0dq\" data-start=\"1974\" data-end=\"2002\"\u003eTemperature Rating: 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"158k442\" data-start=\"2003\" data-end=\"2043\"\u003eControl Type: Fixed toggle mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1xsgawq\" data-start=\"2044\" data-end=\"2101\"\u003eConstruction Features: HACR rated, common trip design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"aqn65c\" data-start=\"2108\" data-end=\"2139\"\u003eStandards \u0026amp; Certifications\u003c\/h2\u003e\n\u003cul data-start=\"2140\" data-end=\"2346\"\u003e\n\u003cli data-section-id=\"ch0whz\" data-start=\"2140\" data-end=\"2157\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"68jafv\" data-start=\"2158\" data-end=\"2187\"\u003eCSA C22.2 No. 5 Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1xqik9e\" data-start=\"2188\" data-end=\"2204\"\u003eCSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"k2kph2\" data-start=\"2205\" data-end=\"2219\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"kep30w\" data-start=\"2220\" data-end=\"2280\"\u003eDesigned for residential electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"19y0f5a\" data-start=\"2281\" data-end=\"2346\"\u003eComplies with standard North American electrical safety codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"r68lcr\" data-start=\"2353\" data-end=\"2377\"\u003eAdditional Features\u003c\/h2\u003e\n\u003cul data-start=\"2378\" data-end=\"2686\"\u003e\n\u003cli data-section-id=\"ft66qd\" data-start=\"2378\" data-end=\"2431\"\u003eAdds two 240V circuits in a single compact device\u003c\/li\u003e\n\u003cli data-section-id=\"h9s1gh\" data-start=\"2432\" data-end=\"2482\"\u003eReduces need for larger load center enclosures\u003c\/li\u003e\n\u003cli data-section-id=\"va8g4z\" data-start=\"2483\" data-end=\"2528\"\u003ePlug-on installation for fast replacement\u003c\/li\u003e\n\u003cli data-section-id=\"1oi4ywe\" data-start=\"2529\" data-end=\"2576\"\u003eReliable thermal-magnetic protection system\u003c\/li\u003e\n\u003cli data-section-id=\"pp62et\" data-start=\"2577\" data-end=\"2636\"\u003eSuitable for HVAC, refrigeration, and residential loads\u003c\/li\u003e\n\u003cli data-section-id=\"13d7q3e\" data-start=\"2637\" data-end=\"2686\"\u003eFactory-configured fixed trip characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"8kd7vi\" data-start=\"2693\" data-end=\"2722\"\u003eManufacturer Information\u003c\/h2\u003e\n\u003cul data-start=\"2723\" data-end=\"2824\"\u003e\n\u003cli data-section-id=\"raqjko\" data-start=\"2723\" data-end=\"2778\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u55619\" data-start=\"2779\" data-end=\"2807\"\u003eBrand: Square D Homeline\u003c\/li\u003e\n\u003cli data-section-id=\"1ruufnb\" data-start=\"2808\" data-end=\"2824\"\u003eSeries: HOMT\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48535864738041,"sku":"HOMT230240","price":95.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/HOMT215220-All-New-1_3a707e15-c9a2-40dc-bdaa-bc38686ec9ba.webp?v=1781611867","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-homeline-homt230240-quad-tandem-2-x-2-pole-30a-40a-miniature-circuit-breaker-plug-on-120-240v-ac","provider":"My Circuit Breakers","version":"1.0","type":"link"}