{"product_id":"square-d-kdl32125-molded-case-circuit-breaker-3-pole-125a-240vac-feed-thru-thermal-magnetic-li-protection","title":"Square D KDL32125 Molded Case Circuit Breaker – 3 Pole – 125A – 240VAC – Feed-Thru – Thermal Magnetic – LI Protection","description":"\u003cp data-start=\"141\" data-end=\"755\"\u003eThe Square D KDL32125 molded case circuit breaker is designed to provide dependable overload and short-circuit protection for commercial and industrial electrical distribution systems. Built for use in \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSchneider Electric\u003c\/span\u003e\u003c\/span\u003e QO 3-phase load centers, switchboards, and compatible enclosures, it features a feed-thru connection for flexible installation. Rated at 125A and 240VAC, the breaker delivers a 25kA interrupting capacity and uses thermal-magnetic trip technology with Long-Time and Instantaneous (LI) protection for reliable circuit safeguarding in demanding environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ombln6\" data-start=\"757\" data-end=\"788\"\u003eVoltage and Current Ratings\u003c\/h3\u003e\n\u003cul data-start=\"790\" data-end=\"906\"\u003e\n\u003cli data-section-id=\"uqz0zm\" data-start=\"790\" data-end=\"818\"\u003eCurrent Rating: 125 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"1cn11yu\" data-start=\"819\" data-end=\"851\"\u003eVoltage Rating: 240 Volts AC\u003c\/li\u003e\n\u003cli data-section-id=\"pvjmxy\" data-start=\"852\" data-end=\"870\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"buto9u\" data-start=\"871\" data-end=\"906\"\u003eContinuous Current Rating: 100%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1uf5u9y\" data-start=\"908\" data-end=\"931\"\u003eInterrupting Rating\u003c\/h3\u003e\n\u003cul data-start=\"933\" data-end=\"1024\"\u003e\n\u003cli data-section-id=\"1i8a4ph\" data-start=\"933\" data-end=\"951\"\u003e25kA at 240VAC\u003c\/li\u003e\n\u003cli data-section-id=\"13orpyq\" data-start=\"952\" data-end=\"982\"\u003eHigh Interrupting Capacity\u003c\/li\u003e\n\u003cli data-section-id=\"tml8qt\" data-start=\"983\" data-end=\"1024\"\u003eStandard Fault Protection Performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"jhcvpz\" data-start=\"1026\" data-end=\"1054\"\u003eTrip Unit and Protection\u003c\/h3\u003e\n\u003cul data-start=\"1056\" data-end=\"1287\"\u003e\n\u003cli data-section-id=\"m4s3sa\" data-start=\"1056\" data-end=\"1131\"\u003eProtection Type:\n\u003cul data-start=\"1077\" data-end=\"1131\"\u003e\n\u003cli data-section-id=\"buuk1w\" data-start=\"1077\" data-end=\"1100\"\u003eOverload Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1v4t4w\" data-start=\"1103\" data-end=\"1131\"\u003eShort-Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vrd4cy\" data-start=\"1132\" data-end=\"1174\"\u003eTrip Unit Technology: Thermal-Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"2qpwk4\" data-start=\"1175\" data-end=\"1236\"\u003eTrip Functions:\n\u003cul data-start=\"1195\" data-end=\"1236\"\u003e\n\u003cli data-section-id=\"61iky8\" data-start=\"1195\" data-end=\"1212\"\u003eLong-Time (L)\u003c\/li\u003e\n\u003cli data-section-id=\"1784m3j\" data-start=\"1215\" data-end=\"1236\"\u003eInstantaneous (I)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"u3y11n\" data-start=\"1237\" data-end=\"1287\"\u003eFixed Thermal and Fixed Magnetic Trip Settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"x3ylao\" data-start=\"1289\" data-end=\"1319\"\u003eConfiguration and Mounting\u003c\/h3\u003e\n\u003cul data-start=\"1321\" data-end=\"1498\"\u003e\n\u003cli data-section-id=\"10zggz9\" data-start=\"1321\" data-end=\"1338\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"afzp65\" data-start=\"1339\" data-end=\"1354\"\u003eSeries: KDL\u003c\/li\u003e\n\u003cli data-section-id=\"1poe18v\" data-start=\"1355\" data-end=\"1385\"\u003eConnection Type: Feed-Thru\u003c\/li\u003e\n\u003cli data-section-id=\"1ovz2pc\" data-start=\"1386\" data-end=\"1415\"\u003eMounting Mode: Unit Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1otynvo\" data-start=\"1416\" data-end=\"1473\"\u003eSuitable for QO 3-Phase Load Centers and Switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"18mx7ug\" data-start=\"1474\" data-end=\"1498\"\u003eControl Type: Toggle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"16isa0t\" data-start=\"1500\" data-end=\"1527\"\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1529\" data-end=\"1605\"\u003e\n\u003cli data-section-id=\"1nbdjus\" data-start=\"1529\" data-end=\"1552\"\u003eTerminal Type: Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"piq00m\" data-start=\"1553\" data-end=\"1605\"\u003eWire Range: 6 AWG to 350 kcmil (Copper\/Aluminum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"cn8pd9\" data-start=\"1607\" data-end=\"1633\"\u003eElectrical Connections\u003c\/h3\u003e\n\u003cul data-start=\"1635\" data-end=\"1684\"\u003e\n\u003cli data-section-id=\"1flpl9v\" data-start=\"1635\" data-end=\"1659\"\u003eLine Connection: Lug\u003c\/li\u003e\n\u003cli data-section-id=\"16lk87v\" data-start=\"1660\" data-end=\"1684\"\u003eLoad Connection: Lug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1lk3oa6\" data-start=\"1686\" data-end=\"1718\"\u003eStandards and Certifications\u003c\/h3\u003e\n\u003cul data-start=\"1720\" data-end=\"1779\"\u003e\n\u003cli data-section-id=\"fjdscg\" data-start=\"1720\" data-end=\"1737\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"1ygh62h\" data-start=\"1738\" data-end=\"1755\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"czvth\" data-start=\"1756\" data-end=\"1779\"\u003eNEMA AB 1 Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"19zqy0x\" data-start=\"1781\" data-end=\"1793\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1795\" data-end=\"2331\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"4xnq46\" data-start=\"1795\" data-end=\"1846\"\u003eSquare D KDL series molded case circuit breaker\u003c\/li\u003e\n\u003cli data-section-id=\"qt16cm\" data-start=\"1847\" data-end=\"1910\"\u003eThermal-magnetic LI protection for reliable circuit control\u003c\/li\u003e\n\u003cli data-section-id=\"mojnx7\" data-start=\"1911\" data-end=\"1957\"\u003eFeed-thru design for flexible installation\u003c\/li\u003e\n\u003cli data-section-id=\"gwz3y8\" data-start=\"1958\" data-end=\"2009\"\u003eHigh interrupting capacity for fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"juweg2\" data-start=\"2010\" data-end=\"2065\"\u003eCompatible with QO 3-phase systems and switchboards\u003c\/li\u003e\n\u003cli data-section-id=\"hbj1xm\" data-start=\"2066\" data-end=\"2141\"\u003eSupports optional accessories such as shunt trip and auxiliary switches\u003c\/li\u003e\n\u003cli data-section-id=\"8ygven\" data-start=\"2142\" data-end=\"2178\"\u003eHACR rated for HVAC applications\u003c\/li\u003e\n\u003cli data-section-id=\"1v9si4k\" data-start=\"2179\" data-end=\"2248\"\u003eDesigned for industrial and commercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"hp6l7c\" data-start=\"2249\" data-end=\"2331\" data-is-last-node=\"\"\u003eManufactured by Schneider Electric for durable electrical protection performance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48537989120249,"sku":"KDL32125","price":279.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/kdl32125_1_c8a3ce4c-64db-4c6a-a290-69374712994b.webp?v=1781635154","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-kdl32125-molded-case-circuit-breaker-3-pole-125a-240vac-feed-thru-thermal-magnetic-li-protection","provider":"My Circuit Breakers","version":"1.0","type":"link"}