{"product_id":"square-d-lap36250-250a-3p-mccb-panel-mounted-600v","title":"Square-D LAP36250 250A 3P MCCB – Panel Mounted – 600V","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\" data-turn-id-container=\"request-WEB:3c7bdf1d-3d3b-48ed-9da5-ef5ceaf3e284-47\" data-is-intersecting=\"true\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:3c7bdf1d-3d3b-48ed-9da5-ef5ceaf3e284-47\" data-turn-id-container=\"request-WEB:3c7bdf1d-3d3b-48ed-9da5-ef5ceaf3e284-47\" data-testid=\"conversation-turn-12\" data-scroll-anchor=\"false\" data-turn=\"assistant\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"9ffd8c76-30f4-43bb-b67a-c423e4e036a7\" dir=\"auto\" data-message-model-slug=\"gpt-5-3-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-turn-start-message=\"true\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-start=\"108\" data-end=\"676\"\u003eThe Square-D LAP36250 is a molded case circuit breaker designed for robust protection of electrical distribution systems in industrial and commercial installations. It features a 250A thermal magnetic non-interchangeable trip unit that ensures reliable protection against overload and short-circuit conditions. Built on the LAP frame platform, it delivers high interrupting performance and stable operation in demanding electrical environments. Its 3-pole, panel-mounted configuration allows straightforward integration into switchboards and power distribution panels.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1h0x0dv\" data-start=\"683\" data-end=\"711\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"686\" data-end=\"711\"\u003eProduct Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"712\" data-end=\"1011\"\u003e\n\u003cli data-section-id=\"qvukzm\" data-start=\"712\" data-end=\"746\"\u003eFrame type: LAP Frame (Type L)\u003c\/li\u003e\n\u003cli data-section-id=\"h9sg9y\" data-start=\"747\" data-end=\"784\"\u003eRated current: 250 Ampere at 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"9mc4zc\" data-start=\"785\" data-end=\"812\"\u003eNumber of poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1b0tru4\" data-start=\"813\" data-end=\"869\"\u003eTrip unit type: Thermal Magnetic Non-interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"1rpqee5\" data-start=\"870\" data-end=\"902\"\u003eMounting type: Panel Mounted\u003c\/li\u003e\n\u003cli data-section-id=\"8h3q4s\" data-start=\"903\" data-end=\"954\"\u003eTerminal configuration: Load End Terminals Only\u003c\/li\u003e\n\u003cli data-section-id=\"19mutrh\" data-start=\"955\" data-end=\"981\"\u003eManufacturer: Square-D\u003c\/li\u003e\n\u003cli data-section-id=\"1cy821i\" data-start=\"982\" data-end=\"1011\"\u003eWarranty: 1 Year In-house\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"15gb1ij\" data-start=\"1018\" data-end=\"1048\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1048\"\u003eTechnical Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1049\" data-end=\"1376\"\u003e\n\u003cli data-section-id=\"1l0b2e8\" data-start=\"1049\" data-end=\"1074\"\u003eTrip range: 1250–2500\u003c\/li\u003e\n\u003cli data-section-id=\"144serl\" data-start=\"1075\" data-end=\"1138\"\u003eProtection functions: Overload and Short Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"jv5qqp\" data-start=\"1139\" data-end=\"1180\"\u003eOperating mechanism: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1ngpfte\" data-start=\"1181\" data-end=\"1217\"\u003eLug type: Standard Load End Only\u003c\/li\u003e\n\u003cli data-section-id=\"jsrdez\" data-start=\"1218\" data-end=\"1287\"\u003eApplication: Industrial and commercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1o7cgko\" data-start=\"1288\" data-end=\"1376\"\u003eMechanical durability: High-strength MCCB design for fault endurance and reliability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"hpn9aw\" data-start=\"1383\" data-end=\"1409\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1386\" data-end=\"1409\"\u003eVoltage and Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1410\" data-end=\"1673\"\u003e\n\u003cli data-section-id=\"1w2n2me\" data-start=\"1410\" data-end=\"1460\"\u003eRated operational voltage: 240 \/ 480 \/ 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"yben6c\" data-start=\"1461\" data-end=\"1483\"\u003eDC rating: 250 VDC\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1484\" data-end=\"1507\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"ksy6tn\" data-start=\"1508\" data-end=\"1620\"\u003eInterrupting capacity:\n\u003cul data-start=\"1535\" data-end=\"1620\"\u003e\n\u003cli data-section-id=\"oydnty\" data-start=\"1535\" data-end=\"1554\"\u003e42 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1hkc2g9\" data-start=\"1557\" data-end=\"1576\"\u003e30 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"d5rhc\" data-start=\"1579\" data-end=\"1598\"\u003e22 kA @ 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"11uasdh\" data-start=\"1601\" data-end=\"1620\"\u003e10 kA @ 250 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19gqqf3\" data-start=\"1621\" data-end=\"1673\"\u003eInsulation level: Industrial-grade MCCB standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"n53vge\" data-start=\"1680\" data-end=\"1699\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1683\" data-end=\"1699\"\u003eProduct Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1700\" data-end=\"1983\"\u003e\n\u003cli data-section-id=\"13t1l21\" data-start=\"1700\" data-end=\"1727\"\u003eProduct model: LAP36250\u003c\/li\u003e\n\u003cli data-section-id=\"1ihxitd\" data-start=\"1728\" data-end=\"1747\"\u003eBrand: Square-D\u003c\/li\u003e\n\u003cli data-section-id=\"jvjs5m\" data-start=\"1748\" data-end=\"1773\"\u003eFrame size: LAP Frame\u003c\/li\u003e\n\u003cli data-section-id=\"12ylc8c\" data-start=\"1774\" data-end=\"1792\"\u003eAmperage: 250A\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"1793\" data-end=\"1810\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"u8x84m\" data-start=\"1811\" data-end=\"1845\"\u003eConnection type: Panel Mounted\u003c\/li\u003e\n\u003cli data-section-id=\"6jm3gn\" data-start=\"1846\" data-end=\"1902\"\u003eApplication type: Electrical distribution protection\u003c\/li\u003e\n\u003cli data-section-id=\"1h2xil9\" data-start=\"1903\" data-end=\"1983\"\u003eAccessories compatibility: Supported and configurable per order requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1yremwj\" data-start=\"1990\" data-end=\"2011\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1993\" data-end=\"2011\"\u003eImportant Note\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2012\" data-end=\"2465\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis product is supplied as a standard base model configuration. Final assembly, accessories, and installation setup may vary depending on application requirements and customer specifications. Accessories can be installed at no additional cost when ordered together with the breaker, provided that installation instructions are clearly specified at the time of purchase. Always ensure technical compatibility before installation or system commissioning.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48405802090745,"sku":"LAP36250-NS","price":3099.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48405802123513,"sku":"LAP36250-CR","price":1199.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LAP36250.webp?v=1778852093","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-lap36250-250a-3p-mccb-panel-mounted-600v","provider":"My Circuit Breakers","version":"1.0","type":"link"}