{"product_id":"square-d-ldl36600u31x-powerpact-mccb-3-pole-600a-600v-feed-thru-electronic-trip-unit-li-molded-case-circuit-breaker","title":"Square D LDL36600U31X PowerPact MCCB – 3 Pole – 600A – 600V – Feed-Thru – Electronic Trip Unit (LI) – Molded Case Circuit Breaker","description":"\u003cp data-start=\"177\" data-end=\"587\"\u003eThe Schneider Electric \/ Square D LDL36600U31X is a PowerPact LDL-series molded case circuit breaker (MCCB) designed for high-capacity industrial power distribution and protection. It provides reliable overload and short-circuit protection for three-phase systems in large commercial and industrial electrical installations, featuring an electronic trip unit and robust feed-thru lug design.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"594\" data-end=\"620\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"598\" data-end=\"620\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"621\" data-end=\"965\"\u003e\n\u003cli data-section-id=\"xd61zq\" data-start=\"621\" data-end=\"658\"\u003eFrame \/ Line Rated Current: 600 A\u003c\/li\u003e\n\u003cli data-section-id=\"1w343n\" data-start=\"659\" data-end=\"693\"\u003eRated Current (Breaker): 600 A\u003c\/li\u003e\n\u003cli data-section-id=\"wj47e3\" data-start=\"694\" data-end=\"728\"\u003eVoltage Rating: up to 600 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"729\" data-end=\"747\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"748\" data-end=\"765\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1i2qukv\" data-start=\"766\" data-end=\"861\"\u003eInterrupting Capacity:\n\u003cul data-start=\"795\" data-end=\"861\"\u003e\n\u003cli data-section-id=\"ynomar\" data-start=\"795\" data-end=\"815\"\u003e18 kA @ 480 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"cdx3b\" data-start=\"818\" data-end=\"838\"\u003e25 kA @ 240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1huzhd1\" data-start=\"841\" data-end=\"861\"\u003e14 kA @ 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l5qh7g\" data-start=\"862\" data-end=\"896\"\u003eContinuous Current Rating: 80%\u003c\/li\u003e\n\u003cli data-section-id=\"1l2ezxj\" data-start=\"897\" data-end=\"965\"\u003eUtilization: Industrial power distribution and feeder protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q9xwgw\" data-start=\"972\" data-end=\"1009\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"976\" data-end=\"1009\"\u003eProtection and Trip Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1010\" data-end=\"1269\"\u003e\n\u003cli data-section-id=\"1rpzykq\" data-start=\"1010\" data-end=\"1075\"\u003eTrip Unit Technology: Electronic (MicroLogic 3.3 standard LI)\u003c\/li\u003e\n\u003cli data-section-id=\"1oqy04j\" data-start=\"1076\" data-end=\"1170\"\u003eProtection Functions:\n\u003cul data-start=\"1104\" data-end=\"1170\"\u003e\n\u003cli data-section-id=\"rifys0\" data-start=\"1104\" data-end=\"1139\"\u003eLong-Time Protection (Overload)\u003c\/li\u003e\n\u003cli data-section-id=\"mfo9bn\" data-start=\"1142\" data-end=\"1170\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q9b5t8\" data-start=\"1171\" data-end=\"1214\"\u003eProtection Type: Solid-state electronic\u003c\/li\u003e\n\u003cli data-section-id=\"vpzr6n\" data-start=\"1215\" data-end=\"1239\"\u003eControl Type: Toggle\u003c\/li\u003e\n\u003cli data-section-id=\"nejvhs\" data-start=\"1240\" data-end=\"1269\"\u003eBreaking Capacity Code: D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"1276\" data-end=\"1310\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1310\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1311\" data-end=\"1639\"\u003e\n\u003cli data-section-id=\"1ln99js\" data-start=\"1311\" data-end=\"1362\"\u003eDevice Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"l4d504\" data-start=\"1363\" data-end=\"1388\"\u003eSeries: PowerPact LDL\u003c\/li\u003e\n\u003cli data-section-id=\"137w3km\" data-start=\"1389\" data-end=\"1431\"\u003eMounting Type: Unit Mount (Lug System)\u003c\/li\u003e\n\u003cli data-section-id=\"wfsdxm\" data-start=\"1432\" data-end=\"1502\"\u003eElectrical Connection: Lugs line \/ lugs load (feed-through design)\u003c\/li\u003e\n\u003cli data-section-id=\"1taa1cw\" data-start=\"1503\" data-end=\"1573\"\u003eApplication Type: High-capacity feeder and distribution protection\u003c\/li\u003e\n\u003cli data-section-id=\"ojgb3j\" data-start=\"1574\" data-end=\"1639\"\u003eCan be used for 2-pole applications (configuration dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1646\" data-end=\"1693\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1650\" data-end=\"1693\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1694\" data-end=\"1927\"\u003e\n\u003cli data-section-id=\"1dyolin\" data-start=\"1694\" data-end=\"1750\"\u003eDimensions (H × W × D): 13.39 in × 5.51 in × 4.33 in\u003c\/li\u003e\n\u003cli data-section-id=\"1hbpqv6\" data-start=\"1751\" data-end=\"1772\"\u003eWeight: 13.67 lbs\u003c\/li\u003e\n\u003cli data-section-id=\"183su4h\" data-start=\"1773\" data-end=\"1827\"\u003eWire Range:\n\u003cul data-start=\"1791\" data-end=\"1827\"\u003e\n\u003cli data-section-id=\"1msomne\" data-start=\"1791\" data-end=\"1827\"\u003e2 × AWG 2\/0 to 500 kcmil (Al\/Cu)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gr6tcr\" data-start=\"1828\" data-end=\"1867\"\u003eHigh-strength industrial MCCB frame\u003c\/li\u003e\n\u003cli data-section-id=\"1u3p35c\" data-start=\"1868\" data-end=\"1927\"\u003eDesigned for heavy-duty electrical distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"13jmbe6\" data-start=\"1934\" data-end=\"1970\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1938\" data-end=\"1970\"\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1971\" data-end=\"2137\"\u003e\n\u003cli data-section-id=\"817qfb\" data-start=\"1971\" data-end=\"1999\"\u003eUL Listed \/ CSA Approved\u003c\/li\u003e\n\u003cli data-section-id=\"14ocpw9\" data-start=\"2000\" data-end=\"2056\"\u003eDesigned for industrial and commercial power systems\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"2057\" data-end=\"2104\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1fhbqsi\" data-start=\"2105\" data-end=\"2137\"\u003eFamily: PowerPact LDL Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kylm4h\" data-start=\"2144\" data-end=\"2160\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2148\" data-end=\"2160\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2161\" data-end=\"2720\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"miesjb\" data-start=\"2161\" data-end=\"2224\"\u003eHigh-capacity 600A MCCB for industrial distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1rro18y\" data-start=\"2225\" data-end=\"2276\"\u003eAdvanced electronic MicroLogic 3.3 LI trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"egtif6\" data-start=\"2277\" data-end=\"2333\"\u003eReliable overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli data-section-id=\"1asurk2\" data-start=\"2334\" data-end=\"2384\"\u003eFeed-thru lug design for flexible installation\u003c\/li\u003e\n\u003cli data-section-id=\"oekp9e\" data-start=\"2385\" data-end=\"2434\"\u003eHigh interrupting capacity up to 18 kA @ 480V\u003c\/li\u003e\n\u003cli data-section-id=\"9zo62b\" data-start=\"2435\" data-end=\"2497\"\u003eSuitable for large feeders, switchboards, and power panels\u003c\/li\u003e\n\u003cli data-section-id=\"nhhpdb\" data-start=\"2498\" data-end=\"2548\"\u003eCompact yet heavy-duty industrial construction\u003c\/li\u003e\n\u003cli data-section-id=\"10uyisc\" data-start=\"2549\" data-end=\"2599\"\u003eCompatible with aluminum and copper conductors\u003c\/li\u003e\n\u003cli data-section-id=\"1bnlpzt\" data-start=\"2600\" data-end=\"2660\"\u003eLong service life with solid-state protection technology\u003c\/li\u003e\n\u003cli data-section-id=\"1o5idns\" data-start=\"2661\" data-end=\"2720\" data-is-last-node=\"\"\u003eDesigned for demanding industrial electrical environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538174292217,"sku":"LDL36600U31X","price":3249.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LDL36600U31X.webp?v=1781642663","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-ldl36600u31x-powerpact-mccb-3-pole-600a-600v-feed-thru-electronic-trip-unit-li-molded-case-circuit-breaker","provider":"My Circuit Breakers","version":"1.0","type":"link"}