{"product_id":"square-d-lrd3365-thermal-overload-relay-80-104a-tesys-deca-series-class-10-motor-protection-relay-for-lc1d80-lc1d95-contactors","title":"Square D LRD3365 Thermal Overload Relay – 80–104A – TeSys Deca Series – Class 10 – Motor Protection Relay for LC1D80\/LC1D95 Contactors","description":"\u003cp data-start=\"182\" data-end=\"524\"\u003eThe Square D \/ Schneider Electric LRD3365 is a thermal overload relay from the TeSys Deca (LRD) series designed for reliable protection of large three-phase motors. It is used with LC1D80 and LC1D95 contactors to protect against overload, phase loss, and stalled rotor conditions in demanding industrial motor applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"531\" data-end=\"557\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"535\" data-end=\"557\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"558\" data-end=\"897\"\u003e\n\u003cli data-section-id=\"yynx5p\" data-start=\"558\" data-end=\"593\"\u003eCurrent Setting Range: 80–104 A\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"594\" data-end=\"612\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"14zhvum\" data-start=\"613\" data-end=\"657\"\u003ePoles: 3 Pole (thermal sensing elements)\u003c\/li\u003e\n\u003cli data-section-id=\"mbxuyx\" data-start=\"658\" data-end=\"706\"\u003eProtection Type: Thermal overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"1td3w4c\" data-start=\"707\" data-end=\"807\"\u003eTrip Class: Class 10 (fast motor protection, trips within ~10 seconds under overload conditions)\u003c\/li\u003e\n\u003cli data-section-id=\"1cpxg3g\" data-start=\"808\" data-end=\"839\"\u003ePhase Loss Sensitivity: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"x4bq8o\" data-start=\"840\" data-end=\"897\"\u003eApplication Type: Motor overload and protection relay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"904\" data-end=\"938\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"908\" data-end=\"938\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"939\" data-end=\"1295\"\u003e\n\u003cli data-section-id=\"cnt9v6\" data-start=\"939\" data-end=\"978\"\u003eDevice Type: Thermal Overload Relay\u003c\/li\u003e\n\u003cli data-section-id=\"l2n30i\" data-start=\"979\" data-end=\"1014\"\u003eSeries: TeSys Deca (LRD Series)\u003c\/li\u003e\n\u003cli data-section-id=\"pym2mv\" data-start=\"1015\" data-end=\"1097\"\u003ePrimary Function: Motor protection (overload, phase failure, stall protection)\u003c\/li\u003e\n\u003cli data-section-id=\"15tswlk\" data-start=\"1098\" data-end=\"1154\"\u003eReset Function: Manual or Automatic reset selectable\u003c\/li\u003e\n\u003cli data-section-id=\"1iquupw\" data-start=\"1155\" data-end=\"1200\"\u003eTrip Mechanism: Thermal bimetallic system\u003c\/li\u003e\n\u003cli data-section-id=\"otge84\" data-start=\"1201\" data-end=\"1248\"\u003eTest Function: Built-in test\/reset function\u003c\/li\u003e\n\u003cli data-section-id=\"1b7ntfw\" data-start=\"1249\" data-end=\"1295\"\u003eTrip Indication: Mechanical trip indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"n07754\" data-start=\"1302\" data-end=\"1323\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1306\" data-end=\"1323\"\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1324\" data-end=\"1534\"\u003e\n\u003cli data-section-id=\"1qfq74t\" data-start=\"1324\" data-end=\"1398\"\u003eSuitable For Use With:\n\u003cul data-start=\"1353\" data-end=\"1398\"\u003e\n\u003cli data-section-id=\"18u3xp0\" data-start=\"1353\" data-end=\"1374\"\u003eLC1D80 contactors\u003c\/li\u003e\n\u003cli data-section-id=\"1oa7vg0\" data-start=\"1377\" data-end=\"1398\"\u003eLC1D95 contactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n54s9d\" data-start=\"1399\" data-end=\"1467\"\u003eSystem Type: Motor starter assembly (contactor + overload relay)\u003c\/li\u003e\n\u003cli data-section-id=\"1obnqqc\" data-start=\"1468\" data-end=\"1534\"\u003eInstallation: Direct mounting under compatible LC1D contactors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1541\" data-end=\"1588\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1545\" data-end=\"1588\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1589\" data-end=\"1922\"\u003e\n\u003cli data-section-id=\"2yo6yz\" data-start=\"1589\" data-end=\"1650\"\u003eMounting Type: DIN rail or plate mount (system dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"1tbp52y\" data-start=\"1651\" data-end=\"1691\"\u003eTerminal Type: Screw clamp terminals\u003c\/li\u003e\n\u003cli data-section-id=\"i60tuw\" data-start=\"1692\" data-end=\"1737\"\u003eCompact modular design for control panels\u003c\/li\u003e\n\u003cli data-section-id=\"oahhiw\" data-start=\"1738\" data-end=\"1806\"\u003eHeavy-duty industrial construction for high-current applications\u003c\/li\u003e\n\u003cli data-section-id=\"11ab6ls\" data-start=\"1807\" data-end=\"1863\"\u003eDesigned for long service life in harsh environments\u003c\/li\u003e\n\u003cli data-section-id=\"3d0u01\" data-start=\"1864\" data-end=\"1922\"\u003eOperating Temperature Range: typically -20 °C to 60 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"edib4p\" data-start=\"1929\" data-end=\"1957\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1933\" data-end=\"1957\"\u003eContacts and Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1958\" data-end=\"2173\"\u003e\n\u003cli data-section-id=\"19qogto\" data-start=\"1958\" data-end=\"1993\"\u003eAuxiliary Contacts: 1 NO + 1 NC\u003c\/li\u003e\n\u003cli data-section-id=\"3w9wy\" data-start=\"1994\" data-end=\"2052\"\u003eContact Function: Trip signaling and interlock control\u003c\/li\u003e\n\u003cli data-section-id=\"gx6eal\" data-start=\"2053\" data-end=\"2101\"\u003eReset Options: Manual \/ Automatic selectable\u003c\/li\u003e\n\u003cli data-section-id=\"18ojn6t\" data-start=\"2102\" data-end=\"2133\"\u003eBuilt-in Test Function: Yes\u003c\/li\u003e\n\u003cli data-section-id=\"1uhlbsg\" data-start=\"2134\" data-end=\"2173\"\u003eMechanical trip indication included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"13jmbe6\" data-start=\"2180\" data-end=\"2216\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2184\" data-end=\"2216\"\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2217\" data-end=\"2496\"\u003e\n\u003cli data-section-id=\"13bqh01\" data-start=\"2217\" data-end=\"2244\"\u003eIEC 60947-4-1 compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1s25z64\" data-start=\"2245\" data-end=\"2279\"\u003eUL \/ CSA \/ CCC \/ EAC certified\u003c\/li\u003e\n\u003cli data-section-id=\"1ab6zhi\" data-start=\"2280\" data-end=\"2317\"\u003eATEX certified (where applicable)\u003c\/li\u003e\n\u003cli data-section-id=\"69c00e\" data-start=\"2318\" data-end=\"2362\"\u003eMarine approvals: DNV-GL, BV, RINA, LROS\u003c\/li\u003e\n\u003cli data-section-id=\"kd8p17\" data-start=\"2363\" data-end=\"2381\"\u003eUKCA compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1lolzyr\" data-start=\"2382\" data-end=\"2408\"\u003eRoHS \/ REACh compliant\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"2409\" data-end=\"2456\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1dqj72a\" data-start=\"2457\" data-end=\"2479\"\u003eSeries: TeSys Deca\u003c\/li\u003e\n\u003cli data-section-id=\"1vkbla0\" data-start=\"2480\" data-end=\"2496\"\u003eMPN: LRD3365\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kylm4h\" data-start=\"2503\" data-end=\"2519\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2507\" data-end=\"2519\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2520\" data-end=\"3040\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1gfyp8k\" data-start=\"2520\" data-end=\"2568\"\u003eAdjustable 80–104A overload protection range\u003c\/li\u003e\n\u003cli data-section-id=\"1cxy2ir\" data-start=\"2569\" data-end=\"2614\"\u003eDesigned for high-power industrial motors\u003c\/li\u003e\n\u003cli data-section-id=\"8kg86v\" data-start=\"2615\" data-end=\"2672\"\u003eClass 10 fast tripping for sensitive motor protection\u003c\/li\u003e\n\u003cli data-section-id=\"173yyi1\" data-start=\"2673\" data-end=\"2723\"\u003ePhase loss detection for enhanced motor safety\u003c\/li\u003e\n\u003cli data-section-id=\"1smfk99\" data-start=\"2724\" data-end=\"2772\"\u003eCompatible with LC1D80 and LC1D95 contactors\u003c\/li\u003e\n\u003cli data-section-id=\"6nl89o\" data-start=\"2773\" data-end=\"2825\"\u003e1NO + 1NC auxiliary contacts for control systems\u003c\/li\u003e\n\u003cli data-section-id=\"18d8mt2\" data-start=\"2826\" data-end=\"2880\"\u003eDirect mounting for compact motor starter assembly\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538198835449,"sku":"LRD3365","price":156.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LRD33__38478.jpg?v=1781644848","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-lrd3365-thermal-overload-relay-80-104a-tesys-deca-series-class-10-motor-protection-relay-for-lc1d80-lc1d95-contactors","provider":"My Circuit Breakers","version":"1.0","type":"link"}