{"product_id":"square-d-lx36100g-100a-3p-mccb-plug-in-mount-600vac","title":"Square-D LX36100G 100A 3P MCCB – Plug-In Mount – 600VAC","description":"\u003cp data-start=\"110\" data-end=\"774\"\u003eThe Square-D LX36100G is a high-performance molded case circuit breaker designed for advanced protection in industrial and commercial electrical distribution systems. Built on the LX (I-Line) frame platform, this breaker features a 600 Amp maximum frame with a 100A electronic non-interchangeable trip unit. It incorporates LSIG trip functions, providing comprehensive protection against long-time overloads, short-time faults, instantaneous short circuits, and ground faults. Its plug-in mounting configuration enables convenient installation and maintenance, while the high interrupting capacity ensures dependable operation in demanding electrical environments.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1h0x0dv\" data-start=\"781\" data-end=\"809\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"784\" data-end=\"809\"\u003eProduct Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"810\" data-end=\"1259\"\u003e\n\u003cli data-section-id=\"79y8z9\" data-start=\"810\" data-end=\"843\"\u003eFrame type: LX (I-Line) Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1m15m0\" data-start=\"844\" data-end=\"875\"\u003eMaximum frame size: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"1m4zb28\" data-start=\"876\" data-end=\"913\"\u003eRated current: 100 Ampere at 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"9mc4zc\" data-start=\"914\" data-end=\"941\"\u003eNumber of poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"172ad23\" data-start=\"942\" data-end=\"992\"\u003eTrip unit type: Electronic Non-interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"igu01f\" data-start=\"993\" data-end=\"1076\"\u003eProtection functions: LSIG (Long-Time, Short-Time, Instantaneous, Ground Fault)\u003c\/li\u003e\n\u003cli data-section-id=\"lfqrsz\" data-start=\"1077\" data-end=\"1103\"\u003eMounting type: Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"oabkd3\" data-start=\"1104\" data-end=\"1146\"\u003eRating plug installed: ARP040 Standard\u003c\/li\u003e\n\u003cli data-section-id=\"n5qo9v\" data-start=\"1147\" data-end=\"1202\"\u003eTerminal configuration: Load End Terminals Standard\u003c\/li\u003e\n\u003cli data-section-id=\"19mutrh\" data-start=\"1203\" data-end=\"1229\"\u003eManufacturer: Square-D\u003c\/li\u003e\n\u003cli data-section-id=\"1cy821i\" data-start=\"1230\" data-end=\"1259\"\u003eWarranty: 1 Year In-house\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"15gb1ij\" data-start=\"1266\" data-end=\"1296\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1269\" data-end=\"1296\"\u003eTechnical Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1297\" data-end=\"1708\"\u003e\n\u003cli data-section-id=\"1v60948\" data-start=\"1297\" data-end=\"1362\"\u003eElectronic trip technology for precise protection performance\u003c\/li\u003e\n\u003cli data-section-id=\"1u72hhi\" data-start=\"1363\" data-end=\"1407\"\u003eIntegrated LSIG protection functionality\u003c\/li\u003e\n\u003cli data-section-id=\"1ktsekj\" data-start=\"1408\" data-end=\"1460\"\u003eOperating mechanism: Electronic trip MCCB system\u003c\/li\u003e\n\u003cli data-section-id=\"h8p2ee\" data-start=\"1461\" data-end=\"1492\"\u003eLug type: Standard Load End\u003c\/li\u003e\n\u003cli data-section-id=\"jsrdez\" data-start=\"1493\" data-end=\"1562\"\u003eApplication: Industrial and commercial power distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"3xguqt\" data-start=\"1563\" data-end=\"1646\"\u003eMechanical construction: Heavy-duty molded case design for high fault endurance\u003c\/li\u003e\n\u003cli data-section-id=\"fh0v5g\" data-start=\"1647\" data-end=\"1708\"\u003eSuitable for I-Line distribution systems and switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"hpn9aw\" data-start=\"1715\" data-end=\"1741\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1718\" data-end=\"1741\"\u003eVoltage and Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1742\" data-end=\"1990\"\u003e\n\u003cli data-section-id=\"1w2n2me\" data-start=\"1742\" data-end=\"1792\"\u003eRated operational voltage: 240 \/ 480 \/ 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"256yka\" data-start=\"1793\" data-end=\"1821\"\u003eMaximum voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"1gofju0\" data-start=\"1822\" data-end=\"1845\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"rcqekw\" data-start=\"1846\" data-end=\"1937\"\u003eInterrupting capacity:\n\u003cul data-start=\"1873\" data-end=\"1937\"\u003e\n\u003cli data-section-id=\"v7rvn5\" data-start=\"1873\" data-end=\"1893\"\u003e100 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ga5ma1\" data-start=\"1896\" data-end=\"1915\"\u003e65 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"5qa87a\" data-start=\"1918\" data-end=\"1937\"\u003e35 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19gqqf3\" data-start=\"1938\" data-end=\"1990\"\u003eInsulation level: Industrial-grade MCCB standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"n53vge\" data-start=\"1997\" data-end=\"2016\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2000\" data-end=\"2016\"\u003eProduct Data\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2017\" data-end=\"2369\"\u003e\n\u003cli data-section-id=\"ihumup\" data-start=\"2017\" data-end=\"2044\"\u003eProduct model: LX36100G\u003c\/li\u003e\n\u003cli data-section-id=\"1ihxitd\" data-start=\"2045\" data-end=\"2064\"\u003eBrand: Square-D\u003c\/li\u003e\n\u003cli data-section-id=\"z3j4nz\" data-start=\"2065\" data-end=\"2103\"\u003eFrame size: LX (I-Line) 600A Frame\u003c\/li\u003e\n\u003cli data-section-id=\"163iscq\" data-start=\"2104\" data-end=\"2122\"\u003eAmperage: 100A\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"2123\" data-end=\"2140\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1gtblq0\" data-start=\"2141\" data-end=\"2169\"\u003eConnection type: Plug-In\u003c\/li\u003e\n\u003cli data-section-id=\"1c7x1o7\" data-start=\"2170\" data-end=\"2212\"\u003eRating plug: ARP040 Installed Standard\u003c\/li\u003e\n\u003cli data-section-id=\"1cro9rk\" data-start=\"2213\" data-end=\"2285\"\u003eApplication type: Advanced power distribution and circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1i6jg3b\" data-start=\"2286\" data-end=\"2369\"\u003eAccessories compatibility: Supported and configurable per customer requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1yremwj\" data-start=\"2376\" data-end=\"2397\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2379\" data-end=\"2397\"\u003eImportant Note\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2398\" data-end=\"2922\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThis product image represents a standard base model and is intended for identification purposes only. Actual product configuration, accessories, trip settings, and installation setup may vary depending on customer requirements and application specifications. Accessories ordered together with the breaker can be installed at no additional cost when installation details are provided during checkout. Always verify technical compatibility, trip configuration, and application suitability before installation or commissioning.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48408078385401,"sku":"LX36100G-NS","price":5999.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48408078418169,"sku":"LX36100G-CR","price":2199.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LX36100G.webp?v=1778957711","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-lx36100g-100a-3p-mccb-plug-in-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}