{"product_id":"square-d-lx36300-300a-3-pole-molded-case-circuit-breaker-plug-in-mount-600vac","title":"Square D LX36300 300A 3 Pole Molded Case Circuit Breaker – Plug In Mount – 600VAC","description":"\u003cp data-start=\"152\" data-end=\"893\"\u003eThe LX36300 by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e is an LX (I-Line) molded case circuit breaker designed for dependable overcurrent protection in commercial and industrial electrical systems. Equipped with an electronic non-interchangeable trip unit featuring LSI (Long-Time, Short-Time, Instantaneous) protection functions, this breaker provides accurate fault response and effective coordination within power distribution networks. Rated at 300 amperes and built on a 600 amp maximum frame platform, the breaker operates up to 600VAC and includes a factory-installed ARP075 rating plug. Its plug-in mounting configuration and standard load-end terminals allow for efficient installation and reliable operation in demanding environments.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"895\" data-end=\"922\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"923\" data-end=\"1371\"\u003e\n\u003cli data-section-id=\"19mqscg\" data-start=\"923\" data-end=\"949\"\u003eManufacturer: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"gai60s\" data-start=\"950\" data-end=\"975\"\u003eModel Number: LX36300\u003c\/li\u003e\n\u003cli data-section-id=\"c7nu5h\" data-start=\"976\" data-end=\"1021\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"ikzv8n\" data-start=\"1022\" data-end=\"1050\"\u003eFrame Style: LX (I-Line)\u003c\/li\u003e\n\u003cli data-section-id=\"7m92em\" data-start=\"1051\" data-end=\"1077\"\u003eMounting Type: Plug In\u003c\/li\u003e\n\u003cli data-section-id=\"fx46gr\" data-start=\"1078\" data-end=\"1128\"\u003eTrip Unit Type: Electronic Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"pcpgh7\" data-start=\"1129\" data-end=\"1191\"\u003eTrip Functions: LSI (Long-Time, Short-Time, Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"108odj4\" data-start=\"1192\" data-end=\"1221\"\u003eRated Current: 300 Ampere\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"1222\" data-end=\"1249\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"u0qou1\" data-start=\"1250\" data-end=\"1285\"\u003eMaximum Frame Capacity: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"2nlk7a\" data-start=\"1286\" data-end=\"1317\"\u003eStandard Lug Type: Load End\u003c\/li\u003e\n\u003cli data-section-id=\"19sk15e\" data-start=\"1318\" data-end=\"1350\"\u003eRating Plug Included: ARP075\u003c\/li\u003e\n\u003cli data-section-id=\"1pruqjc\" data-start=\"1351\" data-end=\"1371\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1373\" data-end=\"1402\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1403\" data-end=\"1802\"\u003e\n\u003cli data-section-id=\"mlnfar\" data-start=\"1403\" data-end=\"1459\"\u003eCalibrated for operation at 40°C ambient temperature\u003c\/li\u003e\n\u003cli data-section-id=\"noxb9c\" data-start=\"1460\" data-end=\"1517\"\u003eElectronic trip system for precise circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1a9zdqh\" data-start=\"1518\" data-end=\"1558\"\u003eNon-interchangeable trip unit design\u003c\/li\u003e\n\u003cli data-section-id=\"jkc8v8\" data-start=\"1559\" data-end=\"1603\"\u003eSuitable for I-Line distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1n5vxd4\" data-start=\"1604\" data-end=\"1647\"\u003eHigh interrupting capacity construction\u003c\/li\u003e\n\u003cli data-section-id=\"1s3kwga\" data-start=\"1648\" data-end=\"1696\"\u003ePlug-in mounting for simplified installation\u003c\/li\u003e\n\u003cli data-section-id=\"1reqn2s\" data-start=\"1697\" data-end=\"1746\"\u003eStandard load-end terminals factory installed\u003c\/li\u003e\n\u003cli data-section-id=\"1jbfpnd\" data-start=\"1747\" data-end=\"1802\"\u003eDesigned for commercial and industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1804\" data-end=\"1828\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1829\" data-end=\"2056\"\u003e\n\u003cli data-section-id=\"1h35qdj\" data-start=\"1829\" data-end=\"1867\"\u003eMaximum Operating Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"3kudzy\" data-start=\"1868\" data-end=\"1910\"\u003eInterrupting Rating at 240 VAC: 100 kA\u003c\/li\u003e\n\u003cli data-section-id=\"q6uo1y\" data-start=\"1911\" data-end=\"1952\"\u003eInterrupting Rating at 480 VAC: 65 kA\u003c\/li\u003e\n\u003cli data-section-id=\"134qgzt\" data-start=\"1953\" data-end=\"1994\"\u003eInterrupting Rating at 600 VAC: 35 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"1995\" data-end=\"2025\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"14dsc1t\" data-start=\"2026\" data-end=\"2056\"\u003eCurrent Rating: 300 Ampere\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"2058\" data-end=\"2075\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"2076\" data-end=\"2365\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"2076\" data-end=\"2095\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1uw3egm\" data-start=\"2096\" data-end=\"2119\"\u003eSeries: LX (I-Line)\u003c\/li\u003e\n\u003cli data-section-id=\"12oshmn\" data-start=\"2120\" data-end=\"2138\"\u003eModel: LX36300\u003c\/li\u003e\n\u003cli data-section-id=\"s8y6py\" data-start=\"2139\" data-end=\"2162\"\u003eFrame Type: L Frame\u003c\/li\u003e\n\u003cli data-section-id=\"8hhd79\" data-start=\"2163\" data-end=\"2191\"\u003eConnection Type: Plug In\u003c\/li\u003e\n\u003cli data-section-id=\"lqk5xt\" data-start=\"2192\" data-end=\"2222\"\u003ePole Configuration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"yi9nmq\" data-start=\"2223\" data-end=\"2263\"\u003eProtection Type: LSI Electronic Trip\u003c\/li\u003e\n\u003cli data-section-id=\"1yf5aeq\" data-start=\"2264\" data-end=\"2306\"\u003eIncluded Accessory: ARP075 Rating Plug\u003c\/li\u003e\n\u003cli data-section-id=\"ra8p5i\" data-start=\"2307\" data-end=\"2365\"\u003eApplication: Circuit protection and power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2367\" data-end=\"2386\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2387\" data-end=\"2900\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image displayed is for identification purposes only and may not represent the exact breaker configuration supplied. Accessories purchased together with the breaker can be professionally installed according to customer specifications at no additional cost. This breaker includes a one-year in-house warranty covering shipping, repairs, labor, and replacement parts required for recertification. Warranty coverage excludes damage caused by misuse, improper handling, or normal operational wear and tear.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48408816124153,"sku":"LX36300-NS","price":3899.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48408816156921,"sku":"LX36300-CR","price":2299.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LX36300.webp?v=1779004404","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-lx36300-300a-3-pole-molded-case-circuit-breaker-plug-in-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}