{"product_id":"square-d-lxi36100g-100a-3-pole-molded-case-circuit-breaker-plug-in-mount-600vac","title":"Square D LXI36100G 100A 3 Pole Molded Case Circuit Breaker – Plug In Mount – 600VAC","description":"\u003cp data-start=\"154\" data-end=\"912\"\u003eThe LXI36100G by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e is a current-limiting, 100% rated LX (I-Line) molded case circuit breaker designed for high-performance protection in demanding industrial and commercial power distribution systems. It features an electronic non-interchangeable trip unit with LSIG (Long-Time, Short-Time, Instantaneous, Ground Fault) protection functions, providing precise fault detection, enhanced coordination, and improved system safety. Rated at 100 amperes with a 600 amp maximum frame capacity, this breaker operates up to 600VAC and delivers high interrupting performance suitable for critical applications. Its plug-in mounting configuration and standard load-end terminals ensure efficient installation and reliable operation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"914\" data-end=\"941\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"942\" data-end=\"1455\"\u003e\n\u003cli data-section-id=\"19mqscg\" data-start=\"942\" data-end=\"968\"\u003eManufacturer: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1o2xrw0\" data-start=\"969\" data-end=\"996\"\u003eModel Number: LXI36100G\u003c\/li\u003e\n\u003cli data-section-id=\"c7nu5h\" data-start=\"997\" data-end=\"1042\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"o9hr9q\" data-start=\"1043\" data-end=\"1072\"\u003eFrame Style: LXI (I-Line)\u003c\/li\u003e\n\u003cli data-section-id=\"7m92em\" data-start=\"1073\" data-end=\"1099\"\u003eMounting Type: Plug In\u003c\/li\u003e\n\u003cli data-section-id=\"fx46gr\" data-start=\"1100\" data-end=\"1150\"\u003eTrip Unit Type: Electronic Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"1ocaqvj\" data-start=\"1151\" data-end=\"1228\"\u003eTrip Functions: LSIG (Long-Time, Short-Time, Instantaneous, Ground Fault)\u003c\/li\u003e\n\u003cli data-section-id=\"16vwbeq\" data-start=\"1229\" data-end=\"1258\"\u003eRated Current: 100 Ampere\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"1259\" data-end=\"1286\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"u0qou1\" data-start=\"1287\" data-end=\"1322\"\u003eMaximum Frame Capacity: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"mqchc4\" data-start=\"1323\" data-end=\"1369\"\u003eRated Design: 100% Rated, Current Limiting\u003c\/li\u003e\n\u003cli data-section-id=\"2nlk7a\" data-start=\"1370\" data-end=\"1401\"\u003eStandard Lug Type: Load End\u003c\/li\u003e\n\u003cli data-section-id=\"19sjad0\" data-start=\"1402\" data-end=\"1434\"\u003eRating Plug Included: ARP040\u003c\/li\u003e\n\u003cli data-section-id=\"1pruqjc\" data-start=\"1435\" data-end=\"1455\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1457\" data-end=\"1486\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1487\" data-end=\"1957\"\u003e\n\u003cli data-section-id=\"mlnfar\" data-start=\"1487\" data-end=\"1543\"\u003eCalibrated for operation at 40°C ambient temperature\u003c\/li\u003e\n\u003cli data-section-id=\"j86w25\" data-start=\"1544\" data-end=\"1615\"\u003eCurrent-limiting breaker design for enhanced protection performance\u003c\/li\u003e\n\u003cli data-section-id=\"n59jh0\" data-start=\"1616\" data-end=\"1670\"\u003eElectronic trip system for accurate fault response\u003c\/li\u003e\n\u003cli data-section-id=\"8v6xab\" data-start=\"1671\" data-end=\"1720\"\u003eIntegrated ground fault protection capability\u003c\/li\u003e\n\u003cli data-section-id=\"k4jgx2\" data-start=\"1721\" data-end=\"1767\"\u003eNon-interchangeable trip unit construction\u003c\/li\u003e\n\u003cli data-section-id=\"ndtfk8\" data-start=\"1768\" data-end=\"1823\"\u003eDesigned for I-Line electrical distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"1s3kwga\" data-start=\"1824\" data-end=\"1872\"\u003ePlug-in mounting for simplified installation\u003c\/li\u003e\n\u003cli data-section-id=\"1n5vxd4\" data-start=\"1873\" data-end=\"1916\"\u003eHigh interrupting capacity construction\u003c\/li\u003e\n\u003cli data-section-id=\"1p6c8ci\" data-start=\"1917\" data-end=\"1957\"\u003eFactory-installed load-end terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1959\" data-end=\"1983\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1984\" data-end=\"2213\"\u003e\n\u003cli data-section-id=\"1h35qdj\" data-start=\"1984\" data-end=\"2022\"\u003eMaximum Operating Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"5r6br1\" data-start=\"2023\" data-end=\"2065\"\u003eInterrupting Rating at 240 VAC: 200 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1e3n6rb\" data-start=\"2066\" data-end=\"2108\"\u003eInterrupting Rating at 480 VAC: 200 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1v8illq\" data-start=\"2109\" data-end=\"2151\"\u003eInterrupting Rating at 600 VAC: 100 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"2152\" data-end=\"2182\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"1b109xf\" data-start=\"2183\" data-end=\"2213\"\u003eCurrent Rating: 100 Ampere\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"2215\" data-end=\"2232\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"2233\" data-end=\"2503\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"2233\" data-end=\"2252\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1k6prlr\" data-start=\"2253\" data-end=\"2277\"\u003eSeries: LXI (I-Line)\u003c\/li\u003e\n\u003cli data-section-id=\"yqerw3\" data-start=\"2278\" data-end=\"2298\"\u003eModel: LXI36100G\u003c\/li\u003e\n\u003cli data-section-id=\"s8y6py\" data-start=\"2299\" data-end=\"2322\"\u003eFrame Type: L Frame\u003c\/li\u003e\n\u003cli data-section-id=\"8hhd79\" data-start=\"2323\" data-end=\"2351\"\u003eConnection Type: Plug In\u003c\/li\u003e\n\u003cli data-section-id=\"lqk5xt\" data-start=\"2352\" data-end=\"2382\"\u003ePole Configuration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"5geuit\" data-start=\"2383\" data-end=\"2424\"\u003eProtection Type: LSIG Electronic Trip\u003c\/li\u003e\n\u003cli data-section-id=\"1tpy95f\" data-start=\"2425\" data-end=\"2503\"\u003eApplication: High-performance industrial and commercial circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2505\" data-end=\"2524\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2525\" data-end=\"3023\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image displayed is for identification purposes only and may not represent the exact configuration supplied. Accessories ordered with the breaker can be installed according to customer-specific requirements at no additional cost. This breaker includes a one-year in-house warranty covering shipping, repair services, labor, and replacement parts required for recertification. Warranty coverage excludes damage caused by misuse, improper installation, or normal operational wear and tear.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48408891490553,"sku":"LXI36100G-NS","price":9599.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48408891523321,"sku":"LXI36100G-CR","price":3999.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LXI36100G.webp?v=1779009686","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-lxi36100g-100a-3-pole-molded-case-circuit-breaker-plug-in-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}