{"product_id":"square-d-lxi36125-125a-3-pole-molded-case-circuit-breaker-plug-in-mount-600vac","title":"Square D LXI36125 125A 3 Pole Molded Case Circuit Breaker – Plug In Mount – 600VAC","description":"\u003cp data-start=\"153\" data-end=\"866\"\u003eThe LXI36125 by \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e is a current-limiting, 100% rated LXI (I-Line) molded case circuit breaker designed for high-performance protection in industrial and commercial electrical distribution systems. It features an electronic non-interchangeable trip unit with LSI (Long-Time, Short-Time, Instantaneous) protection functions, ensuring precise fault interruption and reliable system coordination. Rated at 125 amperes with a 600 amp maximum frame, the breaker operates up to 600VAC and delivers high interrupting capacity suitable for demanding applications. Its plug-in mounting configuration and standard load-end terminals provide efficient installation and dependable operation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1wc2bmo\" data-start=\"868\" data-end=\"895\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul data-start=\"896\" data-end=\"1393\"\u003e\n\u003cli data-section-id=\"19mqscg\" data-start=\"896\" data-end=\"922\"\u003eManufacturer: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"j1eihc\" data-start=\"923\" data-end=\"949\"\u003eModel Number: LXI36125\u003c\/li\u003e\n\u003cli data-section-id=\"c7nu5h\" data-start=\"950\" data-end=\"995\"\u003eProduct Type: Molded Case Circuit Breaker\u003c\/li\u003e\n\u003cli data-section-id=\"o9hr9q\" data-start=\"996\" data-end=\"1025\"\u003eFrame Style: LXI (I-Line)\u003c\/li\u003e\n\u003cli data-section-id=\"7m92em\" data-start=\"1026\" data-end=\"1052\"\u003eMounting Type: Plug In\u003c\/li\u003e\n\u003cli data-section-id=\"fx46gr\" data-start=\"1053\" data-end=\"1103\"\u003eTrip Unit Type: Electronic Non-Interchangeable\u003c\/li\u003e\n\u003cli data-section-id=\"pcpgh7\" data-start=\"1104\" data-end=\"1166\"\u003eTrip Functions: LSI (Long-Time, Short-Time, Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"r5fqd\" data-start=\"1167\" data-end=\"1196\"\u003eRated Current: 125 Ampere\u003c\/li\u003e\n\u003cli data-section-id=\"1mjvejc\" data-start=\"1197\" data-end=\"1224\"\u003eNumber of Poles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"u0qou1\" data-start=\"1225\" data-end=\"1260\"\u003eMaximum Frame Capacity: 600 Amp\u003c\/li\u003e\n\u003cli data-section-id=\"mqchc4\" data-start=\"1261\" data-end=\"1307\"\u003eRated Design: 100% Rated, Current Limiting\u003c\/li\u003e\n\u003cli data-section-id=\"2nlk7a\" data-start=\"1308\" data-end=\"1339\"\u003eStandard Lug Type: Load End\u003c\/li\u003e\n\u003cli data-section-id=\"19sik9h\" data-start=\"1340\" data-end=\"1372\"\u003eRating Plug Included: ARP050\u003c\/li\u003e\n\u003cli data-section-id=\"1pruqjc\" data-start=\"1373\" data-end=\"1393\"\u003eWarranty: 1 Year\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"58xi60\" data-start=\"1395\" data-end=\"1424\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1425\" data-end=\"1847\"\u003e\n\u003cli data-section-id=\"mlnfar\" data-start=\"1425\" data-end=\"1481\"\u003eCalibrated for operation at 40°C ambient temperature\u003c\/li\u003e\n\u003cli data-section-id=\"j86w25\" data-start=\"1482\" data-end=\"1553\"\u003eCurrent-limiting breaker design for enhanced protection performance\u003c\/li\u003e\n\u003cli data-section-id=\"h564zd\" data-start=\"1554\" data-end=\"1607\"\u003eElectronic trip system for precise fault response\u003c\/li\u003e\n\u003cli data-section-id=\"k4jgx2\" data-start=\"1608\" data-end=\"1654\"\u003eNon-interchangeable trip unit construction\u003c\/li\u003e\n\u003cli data-section-id=\"16c5ena\" data-start=\"1655\" data-end=\"1699\"\u003eDesigned for I-Line distribution systems\u003c\/li\u003e\n\u003cli data-section-id=\"4ov9bu\" data-start=\"1700\" data-end=\"1762\"\u003ePlug-in mounting configuration for simplified installation\u003c\/li\u003e\n\u003cli data-section-id=\"1n5vxd4\" data-start=\"1763\" data-end=\"1806\"\u003eHigh interrupting capacity construction\u003c\/li\u003e\n\u003cli data-section-id=\"1p6c8ci\" data-start=\"1807\" data-end=\"1847\"\u003eFactory-installed load-end terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"11flra0\" data-start=\"1849\" data-end=\"1873\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-start=\"1874\" data-end=\"2103\"\u003e\n\u003cli data-section-id=\"1h35qdj\" data-start=\"1874\" data-end=\"1912\"\u003eMaximum Operating Voltage: 600 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"5r6br1\" data-start=\"1913\" data-end=\"1955\"\u003eInterrupting Rating at 240 VAC: 200 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1e3n6rb\" data-start=\"1956\" data-end=\"1998\"\u003eInterrupting Rating at 480 VAC: 200 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1v8illq\" data-start=\"1999\" data-end=\"2041\"\u003eInterrupting Rating at 600 VAC: 100 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1ky5wq7\" data-start=\"2042\" data-end=\"2072\"\u003eFrequency Rating: 50\/60 Hz\u003c\/li\u003e\n\u003cli data-section-id=\"3n2vqc\" data-start=\"2073\" data-end=\"2103\"\u003eCurrent Rating: 125 Ampere\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"165x1by\" data-start=\"2105\" data-end=\"2122\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"2123\" data-end=\"2406\"\u003e\n\u003cli data-section-id=\"1ii30bw\" data-start=\"2123\" data-end=\"2142\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1k6prlr\" data-start=\"2143\" data-end=\"2167\"\u003eSeries: LXI (I-Line)\u003c\/li\u003e\n\u003cli data-section-id=\"i9u8qb\" data-start=\"2168\" data-end=\"2187\"\u003eModel: LXI36125\u003c\/li\u003e\n\u003cli data-section-id=\"s8y6py\" data-start=\"2188\" data-end=\"2211\"\u003eFrame Type: L Frame\u003c\/li\u003e\n\u003cli data-section-id=\"8hhd79\" data-start=\"2212\" data-end=\"2240\"\u003eConnection Type: Plug In\u003c\/li\u003e\n\u003cli data-section-id=\"lqk5xt\" data-start=\"2241\" data-end=\"2271\"\u003ePole Configuration: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"yi9nmq\" data-start=\"2272\" data-end=\"2312\"\u003eProtection Type: LSI Electronic Trip\u003c\/li\u003e\n\u003cli data-section-id=\"1dk8o7r\" data-start=\"2313\" data-end=\"2406\"\u003eApplication: Industrial and commercial circuit protection with high interrupting capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rzxvn7\" data-start=\"2408\" data-end=\"2427\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-start=\"2428\" data-end=\"2932\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe product image shown is for identification purposes only and may not represent the exact breaker configuration supplied. Accessories purchased with the breaker can be installed according to customer-specific requirements at no additional cost. This breaker includes a one-year in-house warranty covering shipping, repair services, labor, and replacement parts required for recertification. Warranty coverage excludes damage caused by misuse, improper installation, or normal operational wear and tear.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48408892145913,"sku":"LXI36125-NS","price":5799.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48408892178681,"sku":"LXI36125-CR","price":2779.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/LXI36125.webp?v=1779009923","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-lxi36125-125a-3-pole-molded-case-circuit-breaker-plug-in-mount-600vac","provider":"My Circuit Breakers","version":"1.0","type":"link"}