{"product_id":"square-d-mja36800e10-powerpact-m-frame-mccb-3-pole-800a-i-line-mount-adjustable-trip-molded-case-circuit-breaker","title":"Square D MJA36800E10 PowerPact M-Frame MCCB – 3 Pole – 800A – I-Line Mount – Adjustable Trip – Molded Case Circuit Breaker","description":"\u003cp data-start=\"170\" data-end=\"632\"\u003eThe Square D MJA36800E10 is a PowerPact M-Frame molded case circuit breaker designed for high-capacity industrial power distribution and protection. It is engineered for use in switchboards and panelboards to provide reliable overload and short-circuit protection for three-phase electrical systems. Featuring an adjustable trip unit and I-Line mounting design, it allows flexible coordination and easy installation in industrial applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"639\" data-end=\"665\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"643\" data-end=\"665\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"666\" data-end=\"966\"\u003e\n\u003cli data-section-id=\"1vl043m\" data-start=\"666\" data-end=\"727\"\u003eFrame \/ Rated Current: 300–800 A (adjustable frame range)\u003c\/li\u003e\n\u003cli data-section-id=\"1smgdp3\" data-start=\"728\" data-end=\"771\"\u003eRated Current (Configured): up to 800 A\u003c\/li\u003e\n\u003cli data-section-id=\"18097ed\" data-start=\"772\" data-end=\"800\"\u003eVoltage Rating: 600 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"801\" data-end=\"819\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"820\" data-end=\"837\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"s38zyk\" data-start=\"838\" data-end=\"870\"\u003eInterrupting Capacity: 25 kA\u003c\/li\u003e\n\u003cli data-section-id=\"1l2ezxj\" data-start=\"871\" data-end=\"939\"\u003eUtilization: Industrial power distribution and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"8995at\" data-start=\"940\" data-end=\"966\"\u003eContinuous Rating: 80%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q9xwgw\" data-start=\"973\" data-end=\"1010\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"977\" data-end=\"1010\"\u003eProtection and Trip Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1011\" data-end=\"1280\"\u003e\n\u003cli data-section-id=\"11emid8\" data-start=\"1011\" data-end=\"1064\"\u003eTrip Unit Type: Adjustable electronic trip system\u003c\/li\u003e\n\u003cli data-section-id=\"hu7nw5\" data-start=\"1065\" data-end=\"1154\"\u003eProtection Functions: Overload and short-circuit protection (adjustable coordination)\u003c\/li\u003e\n\u003cli data-section-id=\"1ngbmpo\" data-start=\"1155\" data-end=\"1223\"\u003eTrip Characteristics: Adjustable settings for system selectivity\u003c\/li\u003e\n\u003cli data-section-id=\"9u1113\" data-start=\"1224\" data-end=\"1280\"\u003eApplication Type: Feeder and distribution protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"1287\" data-end=\"1321\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1291\" data-end=\"1321\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1322\" data-end=\"1637\"\u003e\n\u003cli data-section-id=\"1ln99js\" data-start=\"1322\" data-end=\"1373\"\u003eDevice Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"v4l3v5\" data-start=\"1374\" data-end=\"1416\"\u003eSeries: PowerPact M-Frame (MJA Series)\u003c\/li\u003e\n\u003cli data-section-id=\"1b4ibv0\" data-start=\"1417\" data-end=\"1459\"\u003eMounting Type: I-Line Panelboard Mount\u003c\/li\u003e\n\u003cli data-section-id=\"1jamfue\" data-start=\"1460\" data-end=\"1514\"\u003eElectrical Connection: I-Line style plug-in system\u003c\/li\u003e\n\u003cli data-section-id=\"1yzsmik\" data-start=\"1515\" data-end=\"1561\"\u003ePhase Arrangement: ABC phase configuration\u003c\/li\u003e\n\u003cli data-section-id=\"ifxah3\" data-start=\"1562\" data-end=\"1637\"\u003eApplication: Switchboards, panelboards, industrial distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1644\" data-end=\"1691\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1648\" data-end=\"1691\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1692\" data-end=\"1955\"\u003e\n\u003cli data-section-id=\"1w5ogmy\" data-start=\"1692\" data-end=\"1727\"\u003eHeavy-duty M-Frame construction\u003c\/li\u003e\n\u003cli data-section-id=\"1vteps4\" data-start=\"1728\" data-end=\"1781\"\u003eDesigned for high-current industrial applications\u003c\/li\u003e\n\u003cli data-section-id=\"eoosoa\" data-start=\"1782\" data-end=\"1838\"\u003eModular design for easy installation and replacement\u003c\/li\u003e\n\u003cli data-section-id=\"1ne51tf\" data-start=\"1839\" data-end=\"1894\"\u003eSuitable for switchboard and panelboard integration\u003c\/li\u003e\n\u003cli data-section-id=\"kix4z2\" data-start=\"1895\" data-end=\"1955\"\u003eBuilt for long-term industrial operation under high load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"y8sv4o\" data-start=\"1962\" data-end=\"1994\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1966\" data-end=\"1994\"\u003eStandards and Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1995\" data-end=\"2161\"\u003e\n\u003cli data-section-id=\"5um05n\" data-start=\"1995\" data-end=\"2015\"\u003eUL 489 compliant\u003c\/li\u003e\n\u003cli data-section-id=\"g3hgr\" data-start=\"2016\" data-end=\"2041\"\u003eIEC 60947-2 compliant\u003c\/li\u003e\n\u003cli data-section-id=\"5zk61w\" data-start=\"2042\" data-end=\"2083\"\u003eCSA certified (application dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"f8032d\" data-start=\"2084\" data-end=\"2131\"\u003eManufacturer: Schneider Electric \/ Square D\u003c\/li\u003e\n\u003cli data-section-id=\"136q6gd\" data-start=\"2132\" data-end=\"2161\"\u003eSeries: PowerPact M-Frame\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kylm4h\" data-start=\"2168\" data-end=\"2184\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2172\" data-end=\"2184\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2185\" data-end=\"2725\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1lorq0r\" data-start=\"2185\" data-end=\"2230\"\u003eHigh-capacity adjustable 800A MCCB system\u003c\/li\u003e\n\u003cli data-section-id=\"g6f88j\" data-start=\"2231\" data-end=\"2278\"\u003eI-Line plug-in design for fast installation\u003c\/li\u003e\n\u003cli data-section-id=\"xv0y98\" data-start=\"2279\" data-end=\"2336\"\u003eAdjustable trip settings for coordination flexibility\u003c\/li\u003e\n\u003cli data-section-id=\"1izigg1\" data-start=\"2337\" data-end=\"2379\"\u003e25 kA interrupting capacity at 600V AC\u003c\/li\u003e\n\u003cli data-section-id=\"s8a72g\" data-start=\"2380\" data-end=\"2444\"\u003eDesigned for industrial switchboards and distribution panels\u003c\/li\u003e\n\u003cli data-section-id=\"10xxeqn\" data-start=\"2445\" data-end=\"2503\"\u003eRobust M-Frame construction for demanding environments\u003c\/li\u003e\n\u003cli data-section-id=\"1xephuk\" data-start=\"2504\" data-end=\"2554\"\u003eReliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"1nk2ioi\" data-start=\"2555\" data-end=\"2614\"\u003eSuitable for large feeder and distribution applications\u003c\/li\u003e\n\u003cli data-section-id=\"1dyhunz\" data-start=\"2615\" data-end=\"2668\"\u003eModular architecture for maintenance and upgrades\u003c\/li\u003e\n\u003cli data-section-id=\"12acyk1\" data-start=\"2669\" data-end=\"2725\" data-is-last-node=\"\"\u003eLong operational life in heavy-duty electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538267058425,"sku":"MJA36800E10","price":6336.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/SchneiderElectric-SquareD_MGL36800E10_53b63fec-65f3-4c43-9ea9-79c6b71b4516.jpg?v=1781647849","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-mja36800e10-powerpact-m-frame-mccb-3-pole-800a-i-line-mount-adjustable-trip-molded-case-circuit-breaker","provider":"My Circuit Breakers","version":"1.0","type":"link"}