{"product_id":"square-d-mjl36350-powerpact-m-frame-mccb-3-pole-350a-600v-thermal-magnetic-molded-case-circuit-breaker","title":"Square D MJL36350 PowerPact M-Frame MCCB – 3 Pole – 350A – 600V – Thermal Magnetic – Molded Case Circuit Breaker","description":"\u003cp data-start=\"160\" data-end=\"610\"\u003eThe Square D MJL36350 is a PowerPact M-Frame molded case circuit breaker designed for medium-to-high capacity industrial power distribution. It provides reliable thermal-magnetic protection with electronic enhancements (ET 1.0 type) for overload and short-circuit conditions. Built for switchboards and distribution systems, it delivers strong interrupting performance and dependable operation in demanding electrical environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"617\" data-end=\"643\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"621\" data-end=\"643\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"644\" data-end=\"1010\"\u003e\n\u003cli data-section-id=\"zlz9tk\" data-start=\"644\" data-end=\"676\"\u003eFrame \/ Rated Current: 350 A\u003c\/li\u003e\n\u003cli data-section-id=\"sy33ka\" data-start=\"677\" data-end=\"716\"\u003eVoltage Rating: 600 V AC (50\/60 Hz)\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"717\" data-end=\"735\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"736\" data-end=\"753\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"jvwcxg\" data-start=\"754\" data-end=\"863\"\u003eInterrupting Capacity (UL\/CSA\/NOM):\n\u003cul data-start=\"796\" data-end=\"863\"\u003e\n\u003cli data-section-id=\"xr3msx\" data-start=\"796\" data-end=\"817\"\u003e100 kA @ 240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"15ztuo9\" data-start=\"820\" data-end=\"840\"\u003e65 kA @ 480 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1i3zs5j\" data-start=\"843\" data-end=\"863\"\u003e25 kA @ 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1buan2h\" data-start=\"864\" data-end=\"926\"\u003eIEC Ratings:\n\u003cul data-start=\"883\" data-end=\"926\"\u003e\n\u003cli data-section-id=\"1lh68w3\" data-start=\"883\" data-end=\"903\"\u003e50 kA @ 415 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1dy0kzn\" data-start=\"906\" data-end=\"926\"\u003e65 kA @ 240 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l5qh7g\" data-start=\"927\" data-end=\"961\"\u003eContinuous Current Rating: 80%\u003c\/li\u003e\n\u003cli data-section-id=\"vvn4gj\" data-start=\"962\" data-end=\"1010\"\u003eUtilization: Industrial distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q9xwgw\" data-start=\"1017\" data-end=\"1054\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1021\" data-end=\"1054\"\u003eProtection and Trip Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1055\" data-end=\"1379\"\u003e\n\u003cli data-section-id=\"1qgdmuf\" data-start=\"1055\" data-end=\"1123\"\u003eTrip Type: Thermal magnetic with electronic enhancement (ET 1.0)\u003c\/li\u003e\n\u003cli data-section-id=\"1aiy8vi\" data-start=\"1124\" data-end=\"1230\"\u003eProtection Functions:\n\u003cul data-start=\"1152\" data-end=\"1230\"\u003e\n\u003cli data-section-id=\"1pkih3l\" data-start=\"1152\" data-end=\"1185\"\u003eLong-time overload protection\u003c\/li\u003e\n\u003cli data-section-id=\"13z5pen\" data-start=\"1188\" data-end=\"1230\"\u003eInstantaneous short-circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1thl4i6\" data-start=\"1231\" data-end=\"1294\"\u003eTrip Adjustability: 700 to 3500 A range (system configured)\u003c\/li\u003e\n\u003cli data-section-id=\"11c2x9s\" data-start=\"1295\" data-end=\"1340\"\u003eTrip Class: Non-interchangeable trip unit\u003c\/li\u003e\n\u003cli data-section-id=\"1yg27m2\" data-start=\"1341\" data-end=\"1379\"\u003eOperation: Manual operating handle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"1386\" data-end=\"1420\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1390\" data-end=\"1420\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1421\" data-end=\"1770\"\u003e\n\u003cli data-section-id=\"1ln99js\" data-start=\"1421\" data-end=\"1472\"\u003eDevice Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"f4bgo4\" data-start=\"1473\" data-end=\"1513\"\u003eSeries: PowerPact M-Frame (MJ Model)\u003c\/li\u003e\n\u003cli data-section-id=\"1pjrho\" data-start=\"1514\" data-end=\"1543\"\u003eMounting Type: Unit mount\u003c\/li\u003e\n\u003cli data-section-id=\"ilexr4\" data-start=\"1544\" data-end=\"1581\"\u003eTerminal Type: Line and load lugs\u003c\/li\u003e\n\u003cli data-section-id=\"tr85m8\" data-start=\"1582\" data-end=\"1641\"\u003eElectrical Connection: Lug terminals (Al\/Cu compatible)\u003c\/li\u003e\n\u003cli data-section-id=\"8i9yug\" data-start=\"1642\" data-end=\"1704\"\u003eApplication Type: Power distribution and feeder protection\u003c\/li\u003e\n\u003cli data-section-id=\"d5yby\" data-start=\"1705\" data-end=\"1770\"\u003eCategory: Non-interchangeable trip electronic circuit breaker\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1777\" data-end=\"1824\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1781\" data-end=\"1824\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1825\" data-end=\"2139\"\u003e\n\u003cli data-section-id=\"7261gv\" data-start=\"1825\" data-end=\"1881\"\u003eDimensions: 8.27 in (W) × 8.05 in (D) × 12.86 in (H)\u003c\/li\u003e\n\u003cli data-section-id=\"cl901c\" data-start=\"1882\" data-end=\"1930\"\u003eWire Range: (3) 3\/0 AWG to 500 kcmil (Cu\/Al)\u003c\/li\u003e\n\u003cli data-section-id=\"i6754t\" data-start=\"1931\" data-end=\"1975\"\u003eHeavy-duty industrial frame construction\u003c\/li\u003e\n\u003cli data-section-id=\"hrlhsf\" data-start=\"1976\" data-end=\"2021\"\u003eDesigned for switchboards and panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1yjw5gp\" data-start=\"2022\" data-end=\"2097\"\u003eOperating Temperature Range: -13 °F to 158 °F (-25 °C to 70 °C approx.)\u003c\/li\u003e\n\u003cli data-section-id=\"xtrf53\" data-start=\"2098\" data-end=\"2139\"\u003eRobust mechanical switching mechanism\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"y8sv4o\" data-start=\"2146\" data-end=\"2178\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2150\" data-end=\"2178\"\u003eStandards and Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2179\" data-end=\"2391\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2179\" data-end=\"2192\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2193\" data-end=\"2210\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"g3hgr\" data-start=\"2211\" data-end=\"2236\"\u003eIEC 60947-2 compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1jwb9q8\" data-start=\"2237\" data-end=\"2255\"\u003eNEMA compliant\u003c\/li\u003e\n\u003cli data-section-id=\"aaegsv\" data-start=\"2256\" data-end=\"2272\"\u003eNOM approved\u003c\/li\u003e\n\u003cli data-section-id=\"1g63b22\" data-start=\"2273\" data-end=\"2286\"\u003eCE marked\u003c\/li\u003e\n\u003cli data-section-id=\"1lolzyr\" data-start=\"2287\" data-end=\"2313\"\u003eRoHS \/ REACh compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1bszvs5\" data-start=\"2314\" data-end=\"2361\"\u003eManufacturer: Square D \/ Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"136q6gd\" data-start=\"2362\" data-end=\"2391\"\u003eSeries: PowerPact M-Frame\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"kylm4h\" data-start=\"2398\" data-end=\"2414\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2402\" data-end=\"2414\"\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2415\" data-end=\"2998\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1hepi75\" data-start=\"2415\" data-end=\"2468\"\u003eHigh-performance 350A MCCB for industrial systems\u003c\/li\u003e\n\u003cli data-section-id=\"136vofc\" data-start=\"2469\" data-end=\"2524\"\u003eVery high interrupting capacity up to 100 kA @ 240V\u003c\/li\u003e\n\u003cli data-section-id=\"43qgtr\" data-start=\"2525\" data-end=\"2587\"\u003eThermal magnetic protection with electronic ET 1.0 support\u003c\/li\u003e\n\u003cli data-section-id=\"2sfj33\" data-start=\"2588\" data-end=\"2652\"\u003eDesigned for heavy-duty feeder and distribution applications\u003c\/li\u003e\n\u003cli data-section-id=\"j8bu2z\" data-start=\"2653\" data-end=\"2698\"\u003eStrong fault-current withstand capability\u003c\/li\u003e\n\u003cli data-section-id=\"1y1125a\" data-start=\"2699\" data-end=\"2758\"\u003eLug-type line and load terminals for secure connections\u003c\/li\u003e\n\u003cli data-section-id=\"3ggjss\" data-start=\"2759\" data-end=\"2817\"\u003eSuitable for switchboards and industrial power systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538275643641,"sku":"MJL36350","price":5523.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/SchneiderElectric-SquareD_MGL36800E10_addc2900-6a51-40ab-aede-ec786e432f6e.jpg?v=1781648073","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-mjl36350-powerpact-m-frame-mccb-3-pole-350a-600v-thermal-magnetic-molded-case-circuit-breaker","provider":"My Circuit Breakers","version":"1.0","type":"link"}