{"product_id":"square-d-pja36080u41a-powerpact-p-frame-mccb-3-pole-800a-i-line-plug-on-micrologic-3-0a-electronic-trip-circuit-breaker","title":"Square D PJA36080U41A PowerPact P-Frame MCCB – 3 Pole – 800A – I-Line Plug-On – Micrologic 3.0A – Electronic Trip Circuit Breaker","description":"\u003cp data-start=\"177\" data-end=\"623\"\u003eThe Square D PJA36080U41A is a PowerPact P-Frame molded case circuit breaker designed for high-capacity industrial power distribution. It is engineered for use in I-Line panelboards and switchboards, offering reliable protection for large three-phase electrical systems. The unit includes a Micrologic 3.0A electronic trip system providing adjustable long-time and instantaneous protection with enhanced metering functionality.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1vwh4os\" data-start=\"630\" data-end=\"656\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"634\" data-end=\"656\"\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"657\" data-end=\"973\"\u003e\n\u003cli data-section-id=\"18i8bx2\" data-start=\"657\" data-end=\"689\"\u003eFrame \/ Rated Current: 800 A\u003c\/li\u003e\n\u003cli data-section-id=\"x9uvm4\" data-start=\"690\" data-end=\"750\"\u003eVoltage Rating:\n\u003cul data-start=\"712\" data-end=\"750\"\u003e\n\u003cli data-section-id=\"n0dqk5\" data-start=\"712\" data-end=\"735\"\u003e600 V AC (50\/60 Hz)\u003c\/li\u003e\n\u003cli data-section-id=\"1ud6vym\" data-start=\"738\" data-end=\"750\"\u003e250 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"179harl\" data-start=\"751\" data-end=\"769\"\u003ePhase: 3 Phase\u003c\/li\u003e\n\u003cli data-section-id=\"kdtmuq\" data-start=\"770\" data-end=\"787\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-section-id=\"1v7rne9\" data-start=\"788\" data-end=\"881\"\u003eInterrupting Capacity:\n\u003cul data-start=\"817\" data-end=\"881\"\u003e\n\u003cli data-section-id=\"v7rvn5\" data-start=\"817\" data-end=\"837\"\u003e100 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ga5ma1\" data-start=\"840\" data-end=\"859\"\u003e65 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-section-id=\"ekmg7b\" data-start=\"862\" data-end=\"881\"\u003e25 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"8995at\" data-start=\"882\" data-end=\"908\"\u003eContinuous Rating: 80%\u003c\/li\u003e\n\u003cli data-section-id=\"1guonc9\" data-start=\"909\" data-end=\"973\"\u003eApplication: Power distribution \/ switchboards \/ panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"q9xwgw\" data-start=\"980\" data-end=\"1017\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"984\" data-end=\"1017\"\u003eProtection and Trip Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1018\" data-end=\"1383\"\u003e\n\u003cli data-section-id=\"ko9gr5\" data-start=\"1018\" data-end=\"1048\"\u003eTrip Unit Type: Electronic\u003c\/li\u003e\n\u003cli data-section-id=\"1lgnl6i\" data-start=\"1049\" data-end=\"1080\"\u003eTrip Model: Micrologic 3.0A\u003c\/li\u003e\n\u003cli data-section-id=\"nfrxke\" data-start=\"1081\" data-end=\"1187\"\u003eProtection Functions:\n\u003cul data-start=\"1109\" data-end=\"1187\"\u003e\n\u003cli data-section-id=\"tq2nap\" data-start=\"1109\" data-end=\"1142\"\u003eLong-Time Overload Protection\u003c\/li\u003e\n\u003cli data-section-id=\"ri2pof\" data-start=\"1145\" data-end=\"1187\"\u003eInstantaneous Short-Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1m0bt3p\" data-start=\"1188\" data-end=\"1241\"\u003eTrip Function Type: LI (Long-Time, Instantaneous)\u003c\/li\u003e\n\u003cli data-section-id=\"1rl8ao2\" data-start=\"1242\" data-end=\"1265\"\u003eTrip Setting: 800 A\u003c\/li\u003e\n\u003cli data-section-id=\"1x3ihv5\" data-start=\"1266\" data-end=\"1348\"\u003eAdditional Functionality: Ammeter\/metering capability (Micrologic 3.0A series)\u003c\/li\u003e\n\u003cli data-section-id=\"1xp3k8z\" data-start=\"1349\" data-end=\"1383\"\u003eTrip Control: Toggle mechanism\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1pog7sv\" data-start=\"1390\" data-end=\"1424\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1394\" data-end=\"1424\"\u003eConfiguration and Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1425\" data-end=\"1745\"\u003e\n\u003cli data-section-id=\"1ewy0sq\" data-start=\"1425\" data-end=\"1487\"\u003eDevice Type: Molded Case Circuit Breaker (Electronic Trip)\u003c\/li\u003e\n\u003cli data-section-id=\"g304xd\" data-start=\"1488\" data-end=\"1530\"\u003eSeries: PowerPact P-Frame (PJA Series)\u003c\/li\u003e\n\u003cli data-section-id=\"1xoo1t7\" data-start=\"1531\" data-end=\"1573\"\u003eMounting Type: Plug-on (I-Line system)\u003c\/li\u003e\n\u003cli data-section-id=\"cw6ct0\" data-start=\"1574\" data-end=\"1639\"\u003eElectrical Connection: I-Line line connection \/ lug load side\u003c\/li\u003e\n\u003cli data-section-id=\"ccx3uf\" data-start=\"1640\" data-end=\"1663\"\u003eFrame Type: P-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1jzxfcd\" data-start=\"1664\" data-end=\"1692\"\u003ePhase Configuration: ABC\u003c\/li\u003e\n\u003cli data-section-id=\"68rcnh\" data-start=\"1693\" data-end=\"1745\"\u003eApplication: I-Line panelboards and switchboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1i5ken1\" data-start=\"1752\" data-end=\"1799\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1756\" data-end=\"1799\"\u003eMechanical and Physical Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1800\" data-end=\"2105\"\u003e\n\u003cli data-section-id=\"7261gv\" data-start=\"1800\" data-end=\"1856\"\u003eDimensions: 8.27 in (W) × 8.05 in (D) × 12.86 in (H)\u003c\/li\u003e\n\u003cli data-section-id=\"1uxbkuo\" data-start=\"1857\" data-end=\"1905\"\u003eWire Range: (3) 3\/0 AWG to 500 kcmil (Al\/Cu)\u003c\/li\u003e\n\u003cli data-section-id=\"n5oi7e\" data-start=\"1906\" data-end=\"1946\"\u003eHeavy-duty feeder-grade construction\u003c\/li\u003e\n\u003cli data-section-id=\"1sbya3f\" data-start=\"1947\" data-end=\"1995\"\u003eDesigned for high-current industrial systems\u003c\/li\u003e\n\u003cli data-section-id=\"5ko23q\" data-start=\"1996\" data-end=\"2057\"\u003ePlug-on installation for fast integration and replacement\u003c\/li\u003e\n\u003cli data-section-id=\"1n40s9d\" data-start=\"2058\" data-end=\"2105\"\u003eAmbient Temperature Range: -13 °F to 158 °F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"13jmbe6\" data-start=\"2112\" data-end=\"2148\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2116\" data-end=\"2148\"\u003eStandards and Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2149\" data-end=\"2361\"\u003e\n\u003cli data-section-id=\"1w9xzw2\" data-start=\"2149\" data-end=\"2162\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"breav2\" data-start=\"2163\" data-end=\"2180\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1sr0lxk\" data-start=\"2181\" data-end=\"2198\"\u003eIEC compliant\u003c\/li\u003e\n\u003cli data-section-id=\"11bd7u6\" data-start=\"2199\" data-end=\"2235\"\u003eNOM compliant (system dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"1lolzyr\" data-start=\"2236\" data-end=\"2262\"\u003eRoHS \/ REACh compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1bszvs5\" data-start=\"2263\" data-end=\"2310\"\u003eManufacturer: Square D \/ Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"6wfu40\" data-start=\"2311\" data-end=\"2340\"\u003eSeries: PowerPact P-Frame\u003c\/li\u003e\n\u003cli data-section-id=\"1s5sn92\" data-start=\"2341\" data-end=\"2361\"\u003eUNSPSC: 39131702\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538313785593,"sku":"PJA36080U41A","price":10444.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/SchneiderElectric-SquareD_MGA36800E10_bcb75785-8d3d-4717-bd31-9c994be49704.jpg?v=1781649820","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-pja36080u41a-powerpact-p-frame-mccb-3-pole-800a-i-line-plug-on-micrologic-3-0a-electronic-trip-circuit-breaker","provider":"My Circuit Breakers","version":"1.0","type":"link"}