{"product_id":"square-d-pxf36600g-600a-3p-mccb-bolt-on-mount-lsig-trip-unit-600v","title":"Square D PXF36600G 600A 3P MCCB – Bolt-On Mount – LSIG Trip Unit – 600V","description":"\u003cp data-end=\"811\" data-start=\"147\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e PXF36600G is a molded case circuit breaker (MCCB) designed for reliable protection of industrial and commercial electrical distribution systems. It is equipped with a 600 Amp electronic non-interchangeable trip unit featuring LSIG protection functions, providing long-time, short-time, instantaneous, and ground fault protection. Built on the durable PXF frame, this breaker delivers high-performance fault interruption capability in demanding electrical environments. Its 3-pole configuration and bolt-on mounting design ensure secure installation and long-term operational stability in switchgear and panel applications.\u003c\/p\u003e\n\u003ch2 data-end=\"844\" data-start=\"818\" data-section-id=\"194b837\"\u003eProduct Specification\u003c\/h2\u003e\n\u003cul data-end=\"1350\" data-start=\"845\"\u003e\n\u003cli data-end=\"900\" data-start=\"845\" data-section-id=\"raqjko\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"921\" data-start=\"901\" data-section-id=\"19fmqiv\"\u003eModel: PXF36600G\u003c\/li\u003e\n\u003cli data-end=\"941\" data-start=\"922\" data-section-id=\"1kwqi1l\"\u003eFrame Type: PXF\u003c\/li\u003e\n\u003cli data-end=\"994\" data-start=\"942\" data-section-id=\"c6w748\"\u003eBreaker Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-end=\"1013\" data-start=\"995\" data-section-id=\"15hmv59\"\u003eAmperage: 600A\u003c\/li\u003e\n\u003cli data-end=\"1031\" data-start=\"1014\" data-section-id=\"kdtmuq\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-end=\"1072\" data-start=\"1032\" data-section-id=\"mmbq78\"\u003eMounting Type: Bolt-On (Panel Mount)\u003c\/li\u003e\n\u003cli data-end=\"1118\" data-start=\"1073\" data-section-id=\"19munab\"\u003eTrip Unit: Electronic Non-interchangeable\u003c\/li\u003e\n\u003cli data-end=\"1196\" data-start=\"1119\" data-section-id=\"18ee7gv\"\u003eTrip Functions: LSIG (Long-time, Short-time, Instantaneous, Ground Fault)\u003c\/li\u003e\n\u003cli data-end=\"1222\" data-start=\"1197\" data-section-id=\"snj3ha\"\u003eSensor Size: 1200 Amp\u003c\/li\u003e\n\u003cli data-end=\"1267\" data-start=\"1223\" data-section-id=\"r1fi7r\"\u003eRating Plug: ARP050 Installed (Standard)\u003c\/li\u003e\n\u003cli data-end=\"1311\" data-start=\"1268\" data-section-id=\"1gza2kk\"\u003eTerminals: Without Terminals (Standard)\u003c\/li\u003e\n\u003cli data-end=\"1350\" data-start=\"1312\" data-section-id=\"1i1y08y\"\u003eWarranty: 1 Year In-house Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1385\" data-start=\"1357\" data-section-id=\"10r0yjv\"\u003eTechnical Specification\u003c\/h2\u003e\n\u003cul data-end=\"1773\" data-start=\"1386\"\u003e\n\u003cli data-end=\"1480\" data-start=\"1386\" data-section-id=\"1n7k5vk\"\u003eInterrupting Capacity:\n\u003cul data-end=\"1480\" data-start=\"1415\"\u003e\n\u003cli data-end=\"1435\" data-start=\"1415\" data-section-id=\"1ssvus6\"\u003e125 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-end=\"1458\" data-start=\"1438\" data-section-id=\"1p0g5iz\"\u003e100 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-end=\"1480\" data-start=\"1461\" data-section-id=\"1hpp8jn\"\u003e65 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1550\" data-start=\"1481\" data-section-id=\"1xj6xfy\"\u003eProtection System: Microprocessor-based electronic LSIG trip unit\u003c\/li\u003e\n\u003cli data-end=\"1612\" data-start=\"1551\" data-section-id=\"1juxjg\"\u003eFrame Construction: Heavy-duty PXF industrial-grade frame\u003c\/li\u003e\n\u003cli data-end=\"1689\" data-start=\"1613\" data-section-id=\"6rropn\"\u003eApplication Type: High fault-level industrial power distribution systems\u003c\/li\u003e\n\u003cli data-end=\"1773\" data-start=\"1690\" data-section-id=\"1ayhrmw\"\u003eProtection Coverage: Full ground fault protection in addition to LSIG functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1804\" data-start=\"1780\" data-section-id=\"11flra0\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-end=\"2089\" data-start=\"1805\"\u003e\n\u003cli data-end=\"1840\" data-start=\"1805\" data-section-id=\"yk4799\"\u003eMaximum Voltage Rating: 600V AC\u003c\/li\u003e\n\u003cli data-end=\"2005\" data-start=\"1841\" data-section-id=\"5wx3yw\"\u003eOperating Voltage Ratings:\n\u003cul data-end=\"2005\" data-start=\"1874\"\u003e\n\u003cli data-end=\"1916\" data-start=\"1874\" data-section-id=\"1845hna\"\u003e240 VAC – 125 kA interrupting capacity\u003c\/li\u003e\n\u003cli data-end=\"1961\" data-start=\"1919\" data-section-id=\"uzw117\"\u003e480 VAC – 100 kA interrupting capacity\u003c\/li\u003e\n\u003cli data-end=\"2005\" data-start=\"1964\" data-section-id=\"xr82w3\"\u003e600 VAC – 65 kA interrupting capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2057\" data-start=\"2006\" data-section-id=\"17p8kf0\"\u003eRated Current: 600A at 40°C ambient temperature\u003c\/li\u003e\n\u003cli data-end=\"2089\" data-start=\"2058\" data-section-id=\"1q9nr3y\"\u003eFrequency: 50\/60 Hz systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2113\" data-start=\"2096\" data-section-id=\"165x1by\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-end=\"2584\" data-start=\"2114\"\u003e\n\u003cli data-end=\"2142\" data-start=\"2114\" data-section-id=\"1pzscpt\"\u003eFrame Series: PXF Series\u003c\/li\u003e\n\u003cli data-end=\"2170\" data-start=\"2143\" data-section-id=\"1uejruk\"\u003eSensor Rating: 1200 Amp\u003c\/li\u003e\n\u003cli data-end=\"2201\" data-start=\"2171\" data-section-id=\"lqk5xt\"\u003ePole Configuration: 3 Pole\u003c\/li\u003e\n\u003cli data-end=\"2230\" data-start=\"2202\" data-section-id=\"nx5s05\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-end=\"2285\" data-start=\"2231\" data-section-id=\"1twpp32\"\u003eTrip Technology: Electronic LSIG protection system\u003c\/li\u003e\n\u003cli data-end=\"2343\" data-start=\"2286\" data-section-id=\"1q6kmwv\"\u003eRating Plug: ARP050 included (standard configuration)\u003c\/li\u003e\n\u003cli data-end=\"2404\" data-start=\"2344\" data-section-id=\"pph8y0\"\u003eTerminal Configuration: No terminals supplied (standard)\u003c\/li\u003e\n\u003cli data-end=\"2496\" data-start=\"2405\" data-section-id=\"17wu003\"\u003eApplication: Industrial feeders, main distribution panels, and commercial power systems\u003c\/li\u003e\n\u003cli data-end=\"2584\" data-start=\"2497\" data-section-id=\"966wki\"\u003eInstallation Flexibility: Accessories can be installed before shipment upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2610\" data-start=\"2591\" data-section-id=\"rzxvn7\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"3032\" data-start=\"2611\"\u003eThis product image represents a base model and is for identification purposes only. Accessories can be installed at no additional cost when ordered together; customers must specify requirements during checkout. The breaker includes a 1-year in-house warranty covering repair, parts, and labor under normal operating conditions. Damage caused by misuse, improper installation, or normal wear is not covered under warranty.\u003c\/p\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48389533892857,"sku":"PXF36600G-NS","price":39999.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48389533925625,"sku":"PXF36600G-CR","price":19999.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/PXF36600G.webp?v=1778503116","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-pxf36600g-600a-3p-mccb-bolt-on-mount-lsig-trip-unit-600v","provider":"My Circuit Breakers","version":"1.0","type":"link"}