{"product_id":"square-d-pxf36800gpl-800a-3p-mccb-bolt-on-mount-with-padlock-lsig-trip-unit-600v","title":"Square D PXF36800GPL 800A 3P MCCB – Bolt-On Mount with Padlock – LSIG Trip Unit – 600V","description":"\u003cdiv data-is-intersecting=\"true\" data-turn-id-container=\"request-WEB:b90bb09a-c6c2-47c8-bb96-9606f9f1b516-37\" class=\"\"\u003e\n\u003cdiv class=\"relative w-full overflow-visible\"\u003e\n\u003csection data-turn=\"assistant\" data-scroll-anchor=\"false\" data-testid=\"conversation-turn-30\" data-turn-id-container=\"request-WEB:b90bb09a-c6c2-47c8-bb96-9606f9f1b516-37\" data-turn-id=\"request-WEB:b90bb09a-c6c2-47c8-bb96-9606f9f1b516-37\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-turn-start-message=\"true\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-5\" dir=\"auto\" data-message-id=\"00bc03e3-1c61-4b2f-852c-396009cac1b6\" data-message-author-role=\"assistant\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\"\u003e\n\u003cp data-end=\"886\" data-start=\"162\"\u003eThe \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e PXF36800GPL is a high-performance molded case circuit breaker (MCCB) designed for industrial and commercial power distribution applications requiring advanced protection and enhanced operational safety. It features an 800 Amp electronic non-interchangeable trip unit with LSIG protection functions, delivering long-time, short-time, instantaneous, and ground fault protection. Built on the rugged PXF frame platform, this breaker ensures dependable operation under high fault current conditions. The integrated padlock attachment provides secure lockout\/tagout capability, making it ideal for critical electrical systems where maintenance safety and controlled access are essential.\u003c\/p\u003e\n\u003ch2 data-end=\"919\" data-start=\"893\" data-section-id=\"194b837\"\u003eProduct Specification\u003c\/h2\u003e\n\u003cul data-end=\"1460\" data-start=\"920\"\u003e\n\u003cli data-end=\"975\" data-start=\"920\" data-section-id=\"raqjko\"\u003eManufacturer: \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eSquare D\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"998\" data-start=\"976\" data-section-id=\"w08bf9\"\u003eModel: PXF36800GPL\u003c\/li\u003e\n\u003cli data-end=\"1018\" data-start=\"999\" data-section-id=\"1kwqi1l\"\u003eFrame Type: PXF\u003c\/li\u003e\n\u003cli data-end=\"1071\" data-start=\"1019\" data-section-id=\"c6w748\"\u003eBreaker Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-end=\"1090\" data-start=\"1072\" data-section-id=\"z0ps2r\"\u003eAmperage: 800A\u003c\/li\u003e\n\u003cli data-end=\"1108\" data-start=\"1091\" data-section-id=\"kdtmuq\"\u003ePoles: 3 Pole\u003c\/li\u003e\n\u003cli data-end=\"1149\" data-start=\"1109\" data-section-id=\"mmbq78\"\u003eMounting Type: Bolt-On (Panel Mount)\u003c\/li\u003e\n\u003cli data-end=\"1195\" data-start=\"1150\" data-section-id=\"19munab\"\u003eTrip Unit: Electronic Non-interchangeable\u003c\/li\u003e\n\u003cli data-end=\"1273\" data-start=\"1196\" data-section-id=\"18ee7gv\"\u003eTrip Functions: LSIG (Long-time, Short-time, Instantaneous, Ground Fault)\u003c\/li\u003e\n\u003cli data-end=\"1299\" data-start=\"1274\" data-section-id=\"snj3ha\"\u003eSensor Size: 1200 Amp\u003c\/li\u003e\n\u003cli data-end=\"1332\" data-start=\"1300\" data-section-id=\"bydegd\"\u003ePadlock Attachment: Included\u003c\/li\u003e\n\u003cli data-end=\"1377\" data-start=\"1333\" data-section-id=\"1anf53n\"\u003eRating Plug: ARP067 Installed (Standard)\u003c\/li\u003e\n\u003cli data-end=\"1421\" data-start=\"1378\" data-section-id=\"1gza2kk\"\u003eTerminals: Without Terminals (Standard)\u003c\/li\u003e\n\u003cli data-end=\"1460\" data-start=\"1422\" data-section-id=\"1i1y08y\"\u003eWarranty: 1 Year In-house Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1495\" data-start=\"1467\" data-section-id=\"10r0yjv\"\u003eTechnical Specification\u003c\/h2\u003e\n\u003cul data-end=\"1900\" data-start=\"1496\"\u003e\n\u003cli data-end=\"1590\" data-start=\"1496\" data-section-id=\"1n7k5vk\"\u003eInterrupting Capacity:\n\u003cul data-end=\"1590\" data-start=\"1525\"\u003e\n\u003cli data-end=\"1545\" data-start=\"1525\" data-section-id=\"1ssvus6\"\u003e125 kA @ 240 VAC\u003c\/li\u003e\n\u003cli data-end=\"1568\" data-start=\"1548\" data-section-id=\"1p0g5iz\"\u003e100 kA @ 480 VAC\u003c\/li\u003e\n\u003cli data-end=\"1590\" data-start=\"1571\" data-section-id=\"1hpp8jn\"\u003e65 kA @ 600 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1660\" data-start=\"1591\" data-section-id=\"1xj6xfy\"\u003eProtection System: Microprocessor-based electronic LSIG trip unit\u003c\/li\u003e\n\u003cli data-end=\"1722\" data-start=\"1661\" data-section-id=\"1juxjg\"\u003eFrame Construction: Heavy-duty PXF industrial-grade frame\u003c\/li\u003e\n\u003cli data-end=\"1802\" data-start=\"1723\" data-section-id=\"q8qn2y\"\u003eSafety Feature: Integrated padlock attachment for lockout\/tagout compliance\u003c\/li\u003e\n\u003cli data-end=\"1900\" data-start=\"1803\" data-section-id=\"iwuytv\"\u003eApplication Type: Industrial feeders, distribution panels, and high fault-level power systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1931\" data-start=\"1907\" data-section-id=\"11flra0\"\u003eVoltage and Ratings\u003c\/h2\u003e\n\u003cul data-end=\"2216\" data-start=\"1932\"\u003e\n\u003cli data-end=\"1967\" data-start=\"1932\" data-section-id=\"yk4799\"\u003eMaximum Voltage Rating: 600V AC\u003c\/li\u003e\n\u003cli data-end=\"2132\" data-start=\"1968\" data-section-id=\"5wx3yw\"\u003eOperating Voltage Ratings:\n\u003cul data-end=\"2132\" data-start=\"2001\"\u003e\n\u003cli data-end=\"2043\" data-start=\"2001\" data-section-id=\"1845hna\"\u003e240 VAC – 125 kA interrupting capacity\u003c\/li\u003e\n\u003cli data-end=\"2088\" data-start=\"2046\" data-section-id=\"uzw117\"\u003e480 VAC – 100 kA interrupting capacity\u003c\/li\u003e\n\u003cli data-end=\"2132\" data-start=\"2091\" data-section-id=\"xr82w3\"\u003e600 VAC – 65 kA interrupting capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2184\" data-start=\"2133\" data-section-id=\"9l1fgy\"\u003eRated Current: 800A at 40°C ambient temperature\u003c\/li\u003e\n\u003cli data-end=\"2216\" data-start=\"2185\" data-section-id=\"1q9nr3y\"\u003eFrequency: 50\/60 Hz systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2240\" data-start=\"2223\" data-section-id=\"165x1by\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-end=\"2770\" data-start=\"2241\"\u003e\n\u003cli data-end=\"2269\" data-start=\"2241\" data-section-id=\"1pzscpt\"\u003eFrame Series: PXF Series\u003c\/li\u003e\n\u003cli data-end=\"2297\" data-start=\"2270\" data-section-id=\"1uejruk\"\u003eSensor Rating: 1200 Amp\u003c\/li\u003e\n\u003cli data-end=\"2328\" data-start=\"2298\" data-section-id=\"lqk5xt\"\u003ePole Configuration: 3 Pole\u003c\/li\u003e\n\u003cli data-end=\"2357\" data-start=\"2329\" data-section-id=\"nx5s05\"\u003eConnection Type: Bolt-On\u003c\/li\u003e\n\u003cli data-end=\"2412\" data-start=\"2358\" data-section-id=\"1twpp32\"\u003eTrip Technology: Electronic LSIG protection system\u003c\/li\u003e\n\u003cli data-end=\"2460\" data-start=\"2413\" data-section-id=\"cesyzp\"\u003eSafety Feature: Padlock attachment included\u003c\/li\u003e\n\u003cli data-end=\"2518\" data-start=\"2461\" data-section-id=\"1garx7f\"\u003eRating Plug: ARP067 included (standard configuration)\u003c\/li\u003e\n\u003cli data-end=\"2579\" data-start=\"2519\" data-section-id=\"pph8y0\"\u003eTerminal Configuration: No terminals supplied (standard)\u003c\/li\u003e\n\u003cli data-end=\"2680\" data-start=\"2580\" data-section-id=\"1qt6vi3\"\u003eApplication: Industrial power distribution systems, feeders, and heavy electrical infrastructure\u003c\/li\u003e\n\u003cli data-end=\"2770\" data-start=\"2681\" data-section-id=\"gs8pp2\"\u003eInstallation Flexibility: Accessories can be installed prior to shipment upon request\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2796\" data-start=\"2777\" data-section-id=\"rzxvn7\"\u003eImportant Note\u003c\/h2\u003e\n\u003cp data-is-only-node=\"\" data-is-last-node=\"\" data-end=\"3227\" data-start=\"2797\"\u003eThis product image represents a base model and is for identification purposes only. Accessories can be installed at no additional cost when ordered together; customers must specify configuration details during checkout. The breaker includes a 1-year in-house warranty covering repair, parts, and labor under normal operating conditions. Damage caused by misuse, improper installation, or normal wear is not covered under warranty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Square D","offers":[{"title":"New Surplus","offer_id":48391547060473,"sku":"PXF36800GPL-NS","price":40999.0,"currency_code":"USD","in_stock":true},{"title":"Certified Reconditioned","offer_id":48391547093241,"sku":"PXF36800GPL-CR","price":20999.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/PXF36800GPL.webp?v=1778527555","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-pxf36800gpl-800a-3p-mccb-bolt-on-mount-with-padlock-lsig-trip-unit-600v","provider":"My Circuit Breakers","version":"1.0","type":"link"}