{"product_id":"square-d-qo3301021-30a-3-pole-120-240v-plug-in-thermal-magnetic-circuit-breaker-w-120v-shunt-trip-10kaic-240v","title":"Square D QO3301021 30A 3 Pole 120\/240V Plug-In Thermal Magnetic Circuit Breaker w\/ 120V Shunt Trip 10kAIC @240V","description":"\u003ch2 data-section-id=\"3kqvxb\" data-start=\"0\" data-end=\"97\"\u003eSquare D QO3301021 30A 3 Pole 120\/240V Plug-In Circuit Breaker w\/ 120V Shunt Trip 10kAIC @240V\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1k8uwy3\" data-start=\"99\" data-end=\"122\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp data-start=\"123\" data-end=\"478\"\u003eThe \u003cstrong data-start=\"127\" data-end=\"149\"\u003eSquare D QO3301021\u003c\/strong\u003e is a \u003cstrong data-start=\"155\" data-end=\"187\"\u003e30 Amp, 3 Pole, 120\/240 Volt\u003c\/strong\u003e plug-in thermal magnetic circuit breaker designed for use in Square D QO load centers and panelboards. This breaker includes a factory-installed \u003cstrong data-start=\"333\" data-end=\"355\"\u003e120V AC shunt trip\u003c\/strong\u003e, allowing the breaker to be remotely tripped for emergency shutdown systems, safety interlocks, or fire alarm integration.\u003c\/p\u003e\n\u003cp data-start=\"480\" data-end=\"771\"\u003eEngineered with Square D’s trusted QO technology, the breaker provides fast and reliable protection against overloads and short circuits. It features a \u003cstrong data-start=\"632\" data-end=\"668\"\u003e10kA interrupting rating at 240V\u003c\/strong\u003e, making it suitable for residential, commercial, and light industrial electrical distribution systems.\u003c\/p\u003e\n\u003cp data-start=\"773\" data-end=\"984\"\u003eThe plug-on mounting design allows for quick installation in compatible \u003cstrong data-start=\"845\" data-end=\"874\"\u003eSquare D QO series panels\u003c\/strong\u003e, while the integrated shunt trip provides remote tripping capability when energized by a 120V control signal.\u003c\/p\u003e\n\u003chr data-start=\"986\" data-end=\"989\"\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"991\" data-end=\"1007\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"1008\" data-end=\"1341\"\u003e\n\u003cli data-section-id=\"4apbv4\" data-start=\"1008\" data-end=\"1050\"\u003e\n\u003cp data-start=\"1010\" data-end=\"1050\"\u003eFactory installed \u003cstrong data-start=\"1028\" data-end=\"1050\"\u003e120V AC Shunt Trip\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1acnmch\" data-start=\"1051\" data-end=\"1097\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1097\"\u003eReliable \u003cstrong data-start=\"1062\" data-end=\"1097\"\u003ethermal magnetic trip mechanism\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qexb6e\" data-start=\"1098\" data-end=\"1136\"\u003e\n\u003cp data-start=\"1100\" data-end=\"1136\"\u003e\u003cstrong data-start=\"1100\" data-end=\"1136\"\u003e10kA interrupting rating at 240V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ysjcd8\" data-start=\"1137\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1139\" data-end=\"1180\"\u003e\u003cstrong data-start=\"1139\" data-end=\"1157\"\u003ePlug-in design\u003c\/strong\u003e for quick installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"121z2yl\" data-start=\"1181\" data-end=\"1243\"\u003e\n\u003cp data-start=\"1183\" data-end=\"1243\"\u003eCompatible with \u003cstrong data-start=\"1199\" data-end=\"1243\"\u003eSquare D QO load centers and panelboards\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n9qes5\" data-start=\"1244\" data-end=\"1297\"\u003e\n\u003cp data-start=\"1246\" data-end=\"1297\"\u003eProvides \u003cstrong data-start=\"1255\" data-end=\"1297\"\u003eremote emergency disconnect capability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dlauri\" data-start=\"1298\" data-end=\"1341\"\u003e\n\u003cp data-start=\"1300\" data-end=\"1341\"\u003eTrusted \u003cstrong data-start=\"1308\" data-end=\"1341\"\u003eSquare D QO series protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1348\" data-end=\"1376\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"859\" data-end=\"874\"\u003eKey Features\u003c\/h2\u003e\n\u003cp data-start=\"876\" data-end=\"1116\"\u003e• 30 Amp breaker\u003cbr data-start=\"892\" data-end=\"895\"\u003e• 3 Pole configuration\u003cbr data-start=\"917\" data-end=\"920\"\u003e• 120\/240 Volt rating\u003cbr data-start=\"941\" data-end=\"944\"\u003e• 10kA interrupting rating @240V\u003cbr data-start=\"976\" data-end=\"979\"\u003e• 120V AC shunt trip installed\u003cbr data-start=\"1009\" data-end=\"1012\"\u003e• Thermal magnetic protection\u003cbr data-start=\"1041\" data-end=\"1044\"\u003e• Plug-in mounting design\u003cbr data-start=\"1069\" data-end=\"1072\"\u003e• Fits Square D QO panels and load centers\u003c\/p\u003e\n\u003chr data-start=\"1118\" data-end=\"1121\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"1123\" data-end=\"1149\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cp data-start=\"1151\" data-end=\"1423\"\u003eManufacturer: Square D\u003cbr data-start=\"1173\" data-end=\"1176\"\u003eSeries: QO\u003cbr data-start=\"1186\" data-end=\"1189\"\u003eCatalog Number: QO3301021\u003cbr data-start=\"1214\" data-end=\"1217\"\u003eBreaker Type: Thermal Magnetic\u003cbr data-start=\"1247\" data-end=\"1250\"\u003eAmperage: 30A\u003cbr data-start=\"1263\" data-end=\"1266\"\u003ePoles: 3\u003cbr data-start=\"1274\" data-end=\"1277\"\u003eVoltage: 120\/240V\u003cbr data-start=\"1294\" data-end=\"1297\"\u003eInterrupt Rating: 10kA @240V\u003cbr data-start=\"1325\" data-end=\"1328\"\u003eShunt Trip Voltage: 120V AC\u003cbr data-start=\"1355\" data-end=\"1358\"\u003eMounting Type: Plug-In\u003cbr data-start=\"1380\" data-end=\"1383\"\u003eApplication: Branch Circuit Protection\u003c\/p\u003e\n\u003chr data-start=\"1425\" data-end=\"1428\"\u003e\n\u003ch1 data-section-id=\"8dxdq5\" data-start=\"1430\" data-end=\"1444\"\u003eProduct Data\u003c\/h1\u003e\n\u003cp data-start=\"1446\" data-end=\"1623\"\u003eBrand: Square D\u003cbr data-start=\"1461\" data-end=\"1464\"\u003eModel: QO3301021\u003cbr data-start=\"1480\" data-end=\"1483\"\u003eAmperage: 30A\u003cbr data-start=\"1496\" data-end=\"1499\"\u003ePoles: 3\u003cbr data-start=\"1507\" data-end=\"1510\"\u003eVoltage: 120\/240V\u003cbr data-start=\"1527\" data-end=\"1530\"\u003eInterrupt Rating: 10kA @240V\u003cbr data-start=\"1558\" data-end=\"1561\"\u003eShunt Trip: 120V AC\u003cbr data-start=\"1580\" data-end=\"1583\"\u003eMounting: Plug-In\u003cbr data-start=\"1600\" data-end=\"1603\"\u003eGTIN: 785901494119\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"My Circuit Breakers","offers":[{"title":"New","offer_id":47500549128441,"sku":null,"price":279.0,"currency_code":"USD","in_stock":true},{"title":"Reconditioned","offer_id":47500549161209,"sku":null,"price":221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/QO3301021_grande_jpg.webp?v=1773261960","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-qo3301021-30a-3-pole-120-240v-plug-in-thermal-magnetic-circuit-breaker-w-120v-shunt-trip-10kaic-240v","provider":"My Circuit Breakers","version":"1.0","type":"link"}