{"product_id":"square-d-qob2110vh-110a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-mount-120-240v","title":"Square D QOB2110VH 110A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On Mount – 120\/240V","description":"\u003cp data-start=\"94\" data-end=\"592\"\u003eThe Square D QOB2110VH Molded Case Circuit Breaker is a high-capacity overcurrent protection device designed for commercial and industrial electrical distribution systems. As part of the QOB Series, this thermal-magnetic circuit breaker provides dependable long-time overload and instantaneous short-circuit protection. Featuring a high interrupting capacity of 22 kAIC and a bolt-on mounting design, it is ideal for applications requiring enhanced fault current protection and secure installation.\u003c\/p\u003e\n\u003ch2 data-section-id=\"k6a4r\" data-start=\"594\" data-end=\"615\"\u003eVoltage and Rating\u003c\/h2\u003e\n\u003cul data-start=\"616\" data-end=\"818\"\u003e\n\u003cli data-section-id=\"unwweb\" data-start=\"616\" data-end=\"642\"\u003eCurrent Rating: 110 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"frlszv\" data-start=\"643\" data-end=\"703\"\u003eVoltage Rating:\n\u003cul data-start=\"663\" data-end=\"703\"\u003e\n\u003cli data-section-id=\"y99pn3\" data-start=\"663\" data-end=\"673\"\u003e120 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"j5d46i\" data-start=\"676\" data-end=\"686\"\u003e240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"blcy3a\" data-start=\"689\" data-end=\"703\"\u003e120\/240 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fv4asu\" data-start=\"704\" data-end=\"720\"\u003ePhase: 1-Phase\u003c\/li\u003e\n\u003cli data-section-id=\"hyahr1\" data-start=\"721\" data-end=\"818\"\u003eInterrupting Capacity:\n\u003cul data-start=\"748\" data-end=\"818\"\u003e\n\u003cli data-section-id=\"vd8exb\" data-start=\"748\" data-end=\"768\"\u003e22 kAIC @ 120 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"g9btgq\" data-start=\"771\" data-end=\"791\"\u003e22 kAIC @ 240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"cskra\" data-start=\"794\" data-end=\"818\"\u003e22 kAIC @ 120\/240 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rkota4\" data-start=\"820\" data-end=\"841\"\u003eKey Specifications\u003c\/h2\u003e\n\u003cul data-start=\"842\" data-end=\"1095\"\u003e\n\u003cli data-section-id=\"q9qzjg\" data-start=\"842\" data-end=\"859\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"2c4uun\" data-start=\"860\" data-end=\"894\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"i9hz6m\" data-start=\"895\" data-end=\"920\"\u003eModel Number: QOB2110VH\u003c\/li\u003e\n\u003cli data-section-id=\"hjxvyt\" data-start=\"921\" data-end=\"934\"\u003eSeries: QOB\u003c\/li\u003e\n\u003cli data-section-id=\"ljdll7\" data-start=\"935\" data-end=\"985\"\u003eProduct Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"54lx10\" data-start=\"986\" data-end=\"1011\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"1012\" data-end=\"1036\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1j404fq\" data-start=\"1037\" data-end=\"1062\"\u003eTerminal Type: Box Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"1o7ufcn\" data-start=\"1063\" data-end=\"1095\"\u003eBreaker Type: Thermal Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1097\" data-end=\"1124\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1125\" data-end=\"1477\"\u003e\n\u003cli data-section-id=\"1ypgmji\" data-start=\"1125\" data-end=\"1160\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1oc74iv\" data-start=\"1161\" data-end=\"1185\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"1n65bjm\" data-start=\"1186\" data-end=\"1280\"\u003eTrip Functions:\n\u003cul data-start=\"1206\" data-end=\"1280\"\u003e\n\u003cli data-section-id=\"1nrva41\" data-start=\"1206\" data-end=\"1237\"\u003eLong-Time Overload Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1o88d4v\" data-start=\"1240\" data-end=\"1280\"\u003eInstantaneous Short-Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t9pt9g\" data-start=\"1281\" data-end=\"1308\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"dxvy1c\" data-start=\"1309\" data-end=\"1389\"\u003eWire Size Range:\n\u003cul data-start=\"1330\" data-end=\"1389\"\u003e\n\u003cli data-section-id=\"3l458e\" data-start=\"1330\" data-end=\"1357\"\u003e4 AWG to 300 kcmil Copper\u003c\/li\u003e\n\u003cli data-section-id=\"1if5ib3\" data-start=\"1360\" data-end=\"1389\"\u003e4 AWG to 300 kcmil Aluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l7z805\" data-start=\"1390\" data-end=\"1420\"\u003eMaximum Wire Size: 300 kcmil\u003c\/li\u003e\n\u003cli data-section-id=\"132lwct\" data-start=\"1421\" data-end=\"1447\"\u003eMinimum Wire Size: 4 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"c9ds44\" data-start=\"1448\" data-end=\"1477\"\u003eOperating Temperature: 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"14bu82z\" data-start=\"1479\" data-end=\"1495\"\u003eCompatibility\u003c\/h2\u003e\n\u003ch3 data-section-id=\"r5y2b1\" data-start=\"1496\" data-end=\"1521\"\u003eSuitable for Use With\u003c\/h3\u003e\n\u003cul data-start=\"1522\" data-end=\"1575\"\u003e\n\u003cli data-section-id=\"qlxsz1\" data-start=\"1522\" data-end=\"1547\"\u003eSquare D NQ Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1m3ahxi\" data-start=\"1548\" data-end=\"1575\"\u003eSquare D NQOD Panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"z4r848\" data-start=\"1577\" data-end=\"1603\"\u003eAccessories and Options\u003c\/h2\u003e\n\u003ch3 data-section-id=\"v6ee9q\" data-start=\"1604\" data-end=\"1616\"\u003eIncluded\u003c\/h3\u003e\n\u003cul data-start=\"1617\" data-end=\"1633\"\u003e\n\u003cli data-section-id=\"kt1qc8\" data-start=\"1617\" data-end=\"1633\"\u003eLoad Side Lugs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1b4833i\" data-start=\"1635\" data-end=\"1659\"\u003eOptional Accessories\u003c\/h3\u003e\n\u003cul data-start=\"1660\" data-end=\"1727\"\u003e\n\u003cli data-section-id=\"k9qb9f\" data-start=\"1660\" data-end=\"1672\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"151kr8w\" data-start=\"1673\" data-end=\"1691\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1g5m8h5\" data-start=\"1692\" data-end=\"1706\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"dqp1fz\" data-start=\"1707\" data-end=\"1727\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"b76q0d\" data-start=\"1729\" data-end=\"1760\"\u003eCertifications and Standards\u003c\/h2\u003e\n\u003cul data-start=\"1761\" data-end=\"1823\"\u003e\n\u003cli data-section-id=\"jpjpc7\" data-start=\"1761\" data-end=\"1776\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"nhpr0e\" data-start=\"1777\" data-end=\"1792\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"11qi724\" data-start=\"1793\" data-end=\"1810\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"1811\" data-end=\"1823\"\u003eHACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1vzx4m7\" data-start=\"1825\" data-end=\"1849\"\u003eConstruction Features\u003c\/h2\u003e\n\u003cul data-start=\"1850\" data-end=\"1978\"\u003e\n\u003cli data-section-id=\"1hvnxya\" data-start=\"1850\" data-end=\"1873\"\u003eVisual Trip Indicator\u003c\/li\u003e\n\u003cli data-section-id=\"1e19l7s\" data-start=\"1874\" data-end=\"1894\"\u003eCommon Trip Design\u003c\/li\u003e\n\u003cli data-section-id=\"13nuymt\" data-start=\"1895\" data-end=\"1923\"\u003eHigh Interrupting Capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1c94cp7\" data-start=\"1924\" data-end=\"1949\"\u003eHACR Rated Construction\u003c\/li\u003e\n\u003cli data-section-id=\"10iplux\" data-start=\"1950\" data-end=\"1978\"\u003eThermal-Magnetic Trip Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1xcjw99\" data-start=\"1980\" data-end=\"2004\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul data-start=\"2005\" data-end=\"2494\"\u003e\n\u003cli data-section-id=\"1gre242\" data-start=\"2005\" data-end=\"2063\"\u003eProvides reliable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-section-id=\"12ll05w\" data-start=\"2064\" data-end=\"2142\"\u003eHigh 22 kAIC interrupt rating supports demanding fault-current applications.\u003c\/li\u003e\n\u003cli data-section-id=\"eppask\" data-start=\"2143\" data-end=\"2228\"\u003eBolt-on mounting ensures secure installation and dependable electrical connections.\u003c\/li\u003e\n\u003cli data-section-id=\"1iqirbu\" data-start=\"2229\" data-end=\"2277\"\u003eCommon-trip operation enhances circuit safety.\u003c\/li\u003e\n\u003cli data-section-id=\"jsci5x\" data-start=\"2278\" data-end=\"2345\"\u003eVisual trip indicator allows quick breaker status identification.\u003c\/li\u003e\n\u003cli data-section-id=\"1tda7hs\" data-start=\"2346\" data-end=\"2409\"\u003eHACR rated for HVAC and refrigeration equipment applications.\u003c\/li\u003e\n\u003cli data-section-id=\"1y9yr8u\" data-start=\"2410\" data-end=\"2494\"\u003eCompatible with multiple field-installable accessories for enhanced functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"2496\" data-end=\"2511\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"2512\" data-end=\"2748\"\u003e\n\u003cli data-section-id=\"173pm5h\" data-start=\"2512\" data-end=\"2555\"\u003eCommercial Electrical Distribution Panels\u003c\/li\u003e\n\u003cli data-section-id=\"vc8hdo\" data-start=\"2556\" data-end=\"2595\"\u003eIndustrial Power Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"q2k5dp\" data-start=\"2596\" data-end=\"2623\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"zwhbd8\" data-start=\"2624\" data-end=\"2651\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1gmb4ma\" data-start=\"2652\" data-end=\"2682\"\u003eMotor and Equipment Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1ozodfb\" data-start=\"2683\" data-end=\"2708\"\u003eNQ and NQOD Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"fkovr1\" data-start=\"2709\" data-end=\"2748\"\u003eHigh Fault Current Electrical Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"r2uxc2\" data-start=\"2750\" data-end=\"2768\"\u003eProduct Summary\u003c\/h2\u003e\n\u003cul data-start=\"2769\" data-end=\"3287\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"8eb5fp\" data-start=\"2769\" data-end=\"2879\"\u003e\n\u003cstrong data-start=\"2771\" data-end=\"2788\"\u003eProduct Name:\u003c\/strong\u003e Square D QOB2110VH 110A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On Mount – 120\/240V\u003c\/li\u003e\n\u003cli data-section-id=\"1h7ypv1\" data-start=\"2880\" data-end=\"2902\"\u003eCurrent Rating: 110A\u003c\/li\u003e\n\u003cli data-section-id=\"2m5lhl\" data-start=\"2903\" data-end=\"2932\"\u003eVoltage Rating: 120\/240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"7wt7j9\" data-start=\"2933\" data-end=\"2943\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"2944\" data-end=\"2968\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1j404fq\" data-start=\"2969\" data-end=\"2994\"\u003eTerminal Type: Box Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"mc7wo4\" data-start=\"2995\" data-end=\"3025\"\u003eProtection: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1qvh1my\" data-start=\"3026\" data-end=\"3075\"\u003eTrip Function: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"mkyodu\" data-start=\"3076\" data-end=\"3103\"\u003eInterrupt Rating: 22 kAIC\u003c\/li\u003e\n\u003cli data-section-id=\"6ivm5h\" data-start=\"3104\" data-end=\"3148\"\u003eWire Size: 4 AWG–300 kcmil Copper\/Aluminum\u003c\/li\u003e\n\u003cli data-section-id=\"b8iegs\" data-start=\"3149\" data-end=\"3184\"\u003eCertifications: UL 489, CSA, HACR\u003c\/li\u003e\n\u003cli data-section-id=\"4h5lbn\" data-start=\"3185\" data-end=\"3287\" data-is-last-node=\"\"\u003eApplication: Commercial and industrial branch circuit protection in high fault-current environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538089095417,"sku":"QOB2110VH","price":302.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/QOB280VH-All-New-1_1_8154e610-6c38-4864-9ddb-bb36dfe22651.jpg?v=1781640648","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-qob2110vh-110a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-mount-120-240v","provider":"My Circuit Breakers","version":"1.0","type":"link"}