{"product_id":"square-d-qob225-25a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-mount-120-240v","title":"Square D QOB225 25A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On Mount – 120\/240V","description":"\u003cp data-start=\"90\" data-end=\"501\"\u003eThe Square D QOB225 Molded Case Circuit Breaker is a reliable overcurrent protection device designed for commercial and industrial electrical distribution systems. As part of the QOB Series, this thermal-magnetic circuit breaker provides long-time overload and instantaneous short-circuit protection. Its bolt-on mounting configuration ensures secure installation in compatible Square D NQ and NQOD panelboards.\u003c\/p\u003e\n\u003ch2 data-section-id=\"k6a4r\" data-start=\"503\" data-end=\"524\"\u003eVoltage and Rating\u003c\/h2\u003e\n\u003cul data-start=\"525\" data-end=\"723\"\u003e\n\u003cli data-section-id=\"nypn3o\" data-start=\"525\" data-end=\"550\"\u003eCurrent Rating: 25 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"16f273o\" data-start=\"551\" data-end=\"610\"\u003eVoltage Rating:\n\u003cul data-start=\"571\" data-end=\"610\"\u003e\n\u003cli data-section-id=\"y99pn3\" data-start=\"571\" data-end=\"581\"\u003e120 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"blcy3a\" data-start=\"584\" data-end=\"598\"\u003e120\/240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1ggoqb9\" data-start=\"601\" data-end=\"610\"\u003e48 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vekl2v\" data-start=\"611\" data-end=\"706\"\u003eInterrupting Capacity:\n\u003cul data-start=\"638\" data-end=\"706\"\u003e\n\u003cli data-section-id=\"owuw8e\" data-start=\"638\" data-end=\"658\"\u003e10 kAIC @ 120 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"1kgrc1j\" data-start=\"661\" data-end=\"685\"\u003e10 kAIC @ 120\/240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"a8ndwg\" data-start=\"688\" data-end=\"706\"\u003e5 kAIC @ 48 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1fv4asu\" data-start=\"707\" data-end=\"723\"\u003ePhase: 1-Phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rkota4\" data-start=\"725\" data-end=\"746\"\u003eKey Specifications\u003c\/h2\u003e\n\u003cul data-start=\"747\" data-end=\"945\"\u003e\n\u003cli data-section-id=\"q9qzjg\" data-start=\"747\" data-end=\"764\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"hjxvyt\" data-start=\"765\" data-end=\"778\"\u003eSeries: QOB\u003c\/li\u003e\n\u003cli data-section-id=\"ljdll7\" data-start=\"779\" data-end=\"829\"\u003eProduct Type: Molded Case Circuit Breaker (MCCB)\u003c\/li\u003e\n\u003cli data-section-id=\"54lx10\" data-start=\"830\" data-end=\"855\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"856\" data-end=\"880\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"y5t81z\" data-start=\"881\" data-end=\"912\"\u003eTerminal Type: Pressure Plate\u003c\/li\u003e\n\u003cli data-section-id=\"1o7ufcn\" data-start=\"913\" data-end=\"945\"\u003eBreaker Type: Thermal Magnetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"947\" data-end=\"974\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"975\" data-end=\"1244\"\u003e\n\u003cli data-section-id=\"1oc74iv\" data-start=\"975\" data-end=\"999\"\u003eTrip Function Code: LI\u003c\/li\u003e\n\u003cli data-section-id=\"jfsz0l\" data-start=\"1000\" data-end=\"1070\"\u003eTrip Function:\n\u003cul data-start=\"1019\" data-end=\"1070\"\u003e\n\u003cli data-section-id=\"9gtck9\" data-start=\"1019\" data-end=\"1041\"\u003eLong-Time Protection\u003c\/li\u003e\n\u003cli data-section-id=\"d4prg3\" data-start=\"1044\" data-end=\"1070\"\u003eInstantaneous Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t9pt9g\" data-start=\"1071\" data-end=\"1098\"\u003eTrip Adjustability: Fixed\u003c\/li\u003e\n\u003cli data-section-id=\"167gdn4\" data-start=\"1099\" data-end=\"1159\"\u003eWire Size Range:\n\u003cul data-start=\"1120\" data-end=\"1159\"\u003e\n\u003cli data-section-id=\"eokon1\" data-start=\"1120\" data-end=\"1139\"\u003e14–8 AWG Aluminum\u003c\/li\u003e\n\u003cli data-section-id=\"hcj3xo\" data-start=\"1142\" data-end=\"1159\"\u003e14–8 AWG Copper\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"7f5uho\" data-start=\"1160\" data-end=\"1187\"\u003eMinimum Wire Size: 14 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"1ebx78f\" data-start=\"1188\" data-end=\"1214\"\u003eMaximum Wire Size: 8 AWG\u003c\/li\u003e\n\u003cli data-section-id=\"c9ds44\" data-start=\"1215\" data-end=\"1244\"\u003eOperating Temperature: 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"14bu82z\" data-start=\"1246\" data-end=\"1262\"\u003eCompatibility\u003c\/h2\u003e\n\u003ch3 data-section-id=\"r5y2b1\" data-start=\"1263\" data-end=\"1288\"\u003eSuitable for Use With\u003c\/h3\u003e\n\u003cul data-start=\"1289\" data-end=\"1342\"\u003e\n\u003cli data-section-id=\"qlxsz1\" data-start=\"1289\" data-end=\"1314\"\u003eSquare D NQ Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"1m3ahxi\" data-start=\"1315\" data-end=\"1342\"\u003eSquare D NQOD Panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"b1wc6y\" data-start=\"1344\" data-end=\"1368\"\u003eAvailable Accessories\u003c\/h2\u003e\n\u003cul data-start=\"1369\" data-end=\"1436\"\u003e\n\u003cli data-section-id=\"k9qb9f\" data-start=\"1369\" data-end=\"1381\"\u003eShunt Trip\u003c\/li\u003e\n\u003cli data-section-id=\"151kr8w\" data-start=\"1382\" data-end=\"1400\"\u003eAuxiliary Switch\u003c\/li\u003e\n\u003cli data-section-id=\"1g5m8h5\" data-start=\"1401\" data-end=\"1415\"\u003eAlarm Switch\u003c\/li\u003e\n\u003cli data-section-id=\"dqp1fz\" data-start=\"1416\" data-end=\"1436\"\u003ePadlock Attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"b76q0d\" data-start=\"1438\" data-end=\"1469\"\u003eCertifications and Standards\u003c\/h2\u003e\n\u003cul data-start=\"1470\" data-end=\"1549\"\u003e\n\u003cli data-section-id=\"jpjpc7\" data-start=\"1470\" data-end=\"1485\"\u003eUL 489 Listed\u003c\/li\u003e\n\u003cli data-section-id=\"nhpr0e\" data-start=\"1486\" data-end=\"1501\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"11qi724\" data-start=\"1502\" data-end=\"1519\"\u003eCSA C22.2 No. 5\u003c\/li\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"1520\" data-end=\"1532\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1o4p4wx\" data-start=\"1533\" data-end=\"1549\"\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1vzx4m7\" data-start=\"1551\" data-end=\"1575\"\u003eConstruction Features\u003c\/h2\u003e\n\u003cul data-start=\"1576\" data-end=\"1664\"\u003e\n\u003cli data-section-id=\"1hvnxya\" data-start=\"1576\" data-end=\"1599\"\u003eVisual Trip Indicator\u003c\/li\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"1600\" data-end=\"1612\"\u003eHACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"1o4p4wx\" data-start=\"1613\" data-end=\"1629\"\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli data-section-id=\"1peslzz\" data-start=\"1630\" data-end=\"1664\"\u003eFixed Thermal-Magnetic Trip Unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1xcjw99\" data-start=\"1666\" data-end=\"1690\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1691\" data-end=\"2125\"\u003e\n\u003cli data-section-id=\"mvxf0e\" data-start=\"1691\" data-end=\"1751\"\u003eProvides dependable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-section-id=\"ti9rud\" data-start=\"1752\" data-end=\"1810\"\u003eBolt-on mounting ensures a secure electrical connection.\u003c\/li\u003e\n\u003cli data-section-id=\"jsci5x\" data-start=\"1811\" data-end=\"1878\"\u003eVisual trip indicator allows quick breaker status identification.\u003c\/li\u003e\n\u003cli data-section-id=\"110xyf9\" data-start=\"1879\" data-end=\"1948\"\u003eHACR rating makes it suitable for HVAC and refrigeration equipment.\u003c\/li\u003e\n\u003cli data-section-id=\"14wyhxg\" data-start=\"1949\" data-end=\"2005\"\u003eCompact design maximizes panelboard space utilization.\u003c\/li\u003e\n\u003cli data-section-id=\"siui5s\" data-start=\"2006\" data-end=\"2063\"\u003eCompatible with multiple field-installable accessories.\u003c\/li\u003e\n\u003cli data-section-id=\"1227813\" data-start=\"2064\" data-end=\"2125\"\u003eManufactured to Square D quality and reliability standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"2127\" data-end=\"2142\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"2143\" data-end=\"2370\"\u003e\n\u003cli data-section-id=\"173pm5h\" data-start=\"2143\" data-end=\"2186\"\u003eCommercial Electrical Distribution Panels\u003c\/li\u003e\n\u003cli data-section-id=\"eo12q5\" data-start=\"2187\" data-end=\"2214\"\u003eIndustrial Control Panels\u003c\/li\u003e\n\u003cli data-section-id=\"zwhbd8\" data-start=\"2215\" data-end=\"2242\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"q2k5dp\" data-start=\"2243\" data-end=\"2270\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"5xdhvf\" data-start=\"2271\" data-end=\"2299\"\u003ePower Distribution Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ozodfb\" data-start=\"2300\" data-end=\"2325\"\u003eNQ and NQOD Panelboards\u003c\/li\u003e\n\u003cli data-section-id=\"11sxly2\" data-start=\"2326\" data-end=\"2370\"\u003eGeneral Electrical Protection Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"r2uxc2\" data-start=\"2372\" data-end=\"2390\"\u003eProduct Summary\u003c\/h2\u003e\n\u003cul data-start=\"2391\" data-end=\"2858\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"181berf\" data-start=\"2391\" data-end=\"2497\"\u003e\n\u003cstrong data-start=\"2393\" data-end=\"2410\"\u003eProduct Name:\u003c\/strong\u003e Square D QOB225 25A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On Mount – 120\/240V\u003c\/li\u003e\n\u003cli data-section-id=\"1jf9n6i\" data-start=\"2498\" data-end=\"2519\"\u003eCurrent Rating: 25A\u003c\/li\u003e\n\u003cli data-section-id=\"1o20pbs\" data-start=\"2520\" data-end=\"2557\"\u003eVoltage Rating: 120\/240V AC, 48V DC\u003c\/li\u003e\n\u003cli data-section-id=\"7wt7j9\" data-start=\"2558\" data-end=\"2568\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"2569\" data-end=\"2593\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"mc7wo4\" data-start=\"2594\" data-end=\"2624\"\u003eProtection: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1qvh1my\" data-start=\"2625\" data-end=\"2674\"\u003eTrip Function: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"zfa1wv\" data-start=\"2675\" data-end=\"2716\"\u003eInterrupt Rating: 10 kAIC AC, 5 kAIC DC\u003c\/li\u003e\n\u003cli data-section-id=\"rocgdb\" data-start=\"2717\" data-end=\"2754\"\u003eWire Size: 14–8 AWG Aluminum\/Copper\u003c\/li\u003e\n\u003cli data-section-id=\"b8iegs\" data-start=\"2755\" data-end=\"2790\"\u003eCertifications: UL 489, CSA, HACR\u003c\/li\u003e\n\u003cli data-section-id=\"tgtv9u\" data-start=\"2791\" data-end=\"2858\" data-is-last-node=\"\"\u003eApplication: Commercial and industrial branch circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538074972409,"sku":"QOB2251021","price":275.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/QOB280VH-All_new-2_549b9f29-c56f-4aff-865d-aa563efb1136_1.jpg?v=1781639553","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-qob225-25a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-mount-120-240v","provider":"My Circuit Breakers","version":"1.0","type":"link"}