{"product_id":"square-d-qob280vh-80a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-mount-120-240v","title":"Square D QOB280VH 80A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On Mount – 120\/240V","description":"\u003cp data-start=\"92\" data-end=\"550\"\u003eThe Square D QOB280VH Molded Case Circuit Breaker is a high-capacity overcurrent protection device designed for commercial and industrial electrical distribution systems. Part of the Square D QO Series, this bolt-on circuit breaker features thermal-magnetic trip technology for dependable overload and short-circuit protection. With a high interrupting rating of 22 kAIC, it is suitable for demanding applications requiring enhanced fault current protection.\u003c\/p\u003e\n\u003ch2 data-section-id=\"k6a4r\" data-start=\"552\" data-end=\"573\"\u003eVoltage and Rating\u003c\/h2\u003e\n\u003cul data-start=\"574\" data-end=\"780\"\u003e\n\u003cli data-section-id=\"o8ftln\" data-start=\"574\" data-end=\"599\"\u003eCurrent Rating: 80 Amps\u003c\/li\u003e\n\u003cli data-section-id=\"17zogwb\" data-start=\"600\" data-end=\"660\"\u003eVoltage Rating:\n\u003cul data-start=\"620\" data-end=\"660\"\u003e\n\u003cli data-section-id=\"y99pn3\" data-start=\"620\" data-end=\"630\"\u003e120 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"blcy3a\" data-start=\"633\" data-end=\"647\"\u003e120\/240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"j5d46i\" data-start=\"650\" data-end=\"660\"\u003e240 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2l4pul\" data-start=\"661\" data-end=\"758\"\u003eInterrupting Capacity:\n\u003cul data-start=\"688\" data-end=\"758\"\u003e\n\u003cli data-section-id=\"vd8exb\" data-start=\"688\" data-end=\"708\"\u003e22 kAIC @ 120 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"cskra\" data-start=\"711\" data-end=\"735\"\u003e22 kAIC @ 120\/240 V AC\u003c\/li\u003e\n\u003cli data-section-id=\"g9btgq\" data-start=\"738\" data-end=\"758\"\u003e22 kAIC @ 240 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"96h9go\" data-start=\"759\" data-end=\"780\"\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"rkota4\" data-start=\"782\" data-end=\"803\"\u003eKey Specifications\u003c\/h2\u003e\n\u003cul data-start=\"804\" data-end=\"1089\"\u003e\n\u003cli data-section-id=\"q9qzjg\" data-start=\"804\" data-end=\"821\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"2c4uun\" data-start=\"822\" data-end=\"856\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1xfnnd2\" data-start=\"857\" data-end=\"881\"\u003eModel Number: QOB280VH\u003c\/li\u003e\n\u003cli data-section-id=\"9cyd1b\" data-start=\"882\" data-end=\"907\"\u003eSeries: QO \/ QOB Series\u003c\/li\u003e\n\u003cli data-section-id=\"1s4vk83\" data-start=\"908\" data-end=\"955\"\u003eProduct Type: Miniature Circuit Breaker (MCB)\u003c\/li\u003e\n\u003cli data-section-id=\"54lx10\" data-start=\"956\" data-end=\"981\"\u003eNumber of Poles: 2-Pole\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"982\" data-end=\"1006\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"1oe2xll\" data-start=\"1007\" data-end=\"1031\"\u003eBreaker Type: Standard\u003c\/li\u003e\n\u003cli data-section-id=\"1ypgmji\" data-start=\"1032\" data-end=\"1067\"\u003eTrip Technology: Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"1u60lp4\" data-start=\"1068\" data-end=\"1089\"\u003eRatings: HACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"1091\" data-end=\"1118\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul data-start=\"1119\" data-end=\"1387\"\u003e\n\u003cli data-section-id=\"17mtv7\" data-start=\"1119\" data-end=\"1198\"\u003eTrip Functions:\n\u003cul data-start=\"1139\" data-end=\"1198\"\u003e\n\u003cli data-section-id=\"4zrn1w\" data-start=\"1139\" data-end=\"1165\"\u003eLong-Time Protection (L)\u003c\/li\u003e\n\u003cli data-section-id=\"1wj7fp7\" data-start=\"1168\" data-end=\"1198\"\u003eInstantaneous Protection (I)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"aegnv6\" data-start=\"1199\" data-end=\"1232\"\u003eElectrical Connection: Box Lugs\u003c\/li\u003e\n\u003cli data-section-id=\"xol2ln\" data-start=\"1233\" data-end=\"1260\"\u003eNumber of Panel Spaces: 2\u003c\/li\u003e\n\u003cli data-section-id=\"12bjonk\" data-start=\"1261\" data-end=\"1337\"\u003eWire Size Range:\n\u003cul data-start=\"1282\" data-end=\"1337\"\u003e\n\u003cli data-section-id=\"eqtk8h\" data-start=\"1282\" data-end=\"1307\"\u003eAWG 4 to AWG 2\/0 Copper\u003c\/li\u003e\n\u003cli data-section-id=\"m83e3k\" data-start=\"1310\" data-end=\"1337\"\u003eAWG 4 to AWG 2\/0 Aluminum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2kxc9\" data-start=\"1338\" data-end=\"1387\"\u003eOperating Temperature:\n\u003cul data-start=\"1365\" data-end=\"1387\"\u003e\n\u003cli data-section-id=\"beq3k5\" data-start=\"1365\" data-end=\"1387\"\u003e104°F (40°C) Ambient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"14b1stp\" data-start=\"1389\" data-end=\"1413\"\u003eDimensions and Weight\u003c\/h2\u003e\n\u003cul data-start=\"1414\" data-end=\"1465\"\u003e\n\u003cli data-section-id=\"m2v4b6\" data-start=\"1414\" data-end=\"1431\"\u003eHeight: 3.50 in\u003c\/li\u003e\n\u003cli data-section-id=\"1ydypzd\" data-start=\"1432\" data-end=\"1448\"\u003eWidth: 1.50 in\u003c\/li\u003e\n\u003cli data-section-id=\"u82zyk\" data-start=\"1449\" data-end=\"1465\"\u003eDepth: 2.91 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"b76q0d\" data-start=\"1467\" data-end=\"1498\"\u003eCertifications and Standards\u003c\/h2\u003e\n\u003cul data-start=\"1499\" data-end=\"1539\"\u003e\n\u003cli data-section-id=\"1qadegi\" data-start=\"1499\" data-end=\"1510\"\u003eUL Listed\u003c\/li\u003e\n\u003cli data-section-id=\"nhpr0e\" data-start=\"1511\" data-end=\"1526\"\u003eCSA Certified\u003c\/li\u003e\n\u003cli data-section-id=\"1m4uh6e\" data-start=\"1527\" data-end=\"1539\"\u003eHACR Rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1xcjw99\" data-start=\"1541\" data-end=\"1565\"\u003eFeatures and Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1566\" data-end=\"2017\"\u003e\n\u003cli data-section-id=\"1gre242\" data-start=\"1566\" data-end=\"1624\"\u003eProvides reliable overload and short-circuit protection.\u003c\/li\u003e\n\u003cli data-section-id=\"no4ypa\" data-start=\"1625\" data-end=\"1689\"\u003eHigh 22 kAIC interrupting capacity for demanding applications.\u003c\/li\u003e\n\u003cli data-section-id=\"17mhlch\" data-start=\"1690\" data-end=\"1753\"\u003eThermal-magnetic trip unit ensures accurate fault protection.\u003c\/li\u003e\n\u003cli data-section-id=\"1y69m8x\" data-start=\"1754\" data-end=\"1826\"\u003eBolt-on mounting offers secure installation and electrical connection.\u003c\/li\u003e\n\u003cli data-section-id=\"1p15j84\" data-start=\"1827\" data-end=\"1899\"\u003eHACR rated for heating, air conditioning, and refrigeration equipment.\u003c\/li\u003e\n\u003cli data-section-id=\"qkrp8q\" data-start=\"1900\" data-end=\"1967\"\u003eCompatible with Square D QOB series load centers and panelboards.\u003c\/li\u003e\n\u003cli data-section-id=\"1z00x71\" data-start=\"1968\" data-end=\"2017\"\u003eCompact design maximizes available panel space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"2019\" data-end=\"2034\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"2035\" data-end=\"2266\"\u003e\n\u003cli data-section-id=\"173pm5h\" data-start=\"2035\" data-end=\"2078\"\u003eCommercial Electrical Distribution Panels\u003c\/li\u003e\n\u003cli data-section-id=\"129rxnq\" data-start=\"2079\" data-end=\"2105\"\u003eIndustrial Power Systems\u003c\/li\u003e\n\u003cli data-section-id=\"q2k5dp\" data-start=\"2106\" data-end=\"2133\"\u003eHVAC Equipment Protection\u003c\/li\u003e\n\u003cli data-section-id=\"zwhbd8\" data-start=\"2134\" data-end=\"2161\"\u003eBranch Circuit Protection\u003c\/li\u003e\n\u003cli data-section-id=\"1gmb4ma\" data-start=\"2162\" data-end=\"2192\"\u003eMotor and Equipment Circuits\u003c\/li\u003e\n\u003cli data-section-id=\"8twqh0\" data-start=\"2193\" data-end=\"2225\"\u003eQO and QOB Series Load Centers\u003c\/li\u003e\n\u003cli data-section-id=\"1k3p4gc\" data-start=\"2226\" data-end=\"2266\"\u003ePanelboards and Distribution Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"we2dfi\" data-start=\"2268\" data-end=\"2283\"\u003eProduct Data\u003c\/h2\u003e\n\u003cul data-start=\"2284\" data-end=\"2416\"\u003e\n\u003cli data-section-id=\"2c4uun\" data-start=\"2284\" data-end=\"2318\"\u003eManufacturer: Schneider Electric\u003c\/li\u003e\n\u003cli data-section-id=\"q9qzjg\" data-start=\"2319\" data-end=\"2336\"\u003eBrand: Square D\u003c\/li\u003e\n\u003cli data-section-id=\"1m0h1fi\" data-start=\"2337\" data-end=\"2360\"\u003ePart Number: QOB280VH\u003c\/li\u003e\n\u003cli data-section-id=\"73qzbe\" data-start=\"2361\" data-end=\"2388\"\u003eAlternate Model: Q0B280VH\u003c\/li\u003e\n\u003cli data-section-id=\"1jntozu\" data-start=\"2389\" data-end=\"2416\"\u003eProduct Family: QO Series\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"r2uxc2\" data-start=\"2418\" data-end=\"2436\"\u003eProduct Summary\u003c\/h2\u003e\n\u003cul data-start=\"2437\" data-end=\"2919\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"1xc2szp\" data-start=\"2437\" data-end=\"2545\"\u003e\n\u003cstrong data-start=\"2439\" data-end=\"2456\"\u003eProduct Name:\u003c\/strong\u003e Square D QOB280VH 80A 2-Pole Thermal Magnetic Circuit Breaker – Bolt-On Mount – 120\/240V\u003c\/li\u003e\n\u003cli data-section-id=\"1jf9eyd\" data-start=\"2546\" data-end=\"2567\"\u003eCurrent Rating: 80A\u003c\/li\u003e\n\u003cli data-section-id=\"2m5lhl\" data-start=\"2568\" data-end=\"2597\"\u003eVoltage Rating: 120\/240V AC\u003c\/li\u003e\n\u003cli data-section-id=\"7wt7j9\" data-start=\"2598\" data-end=\"2608\"\u003ePoles: 2\u003c\/li\u003e\n\u003cli data-section-id=\"av5m2m\" data-start=\"2609\" data-end=\"2633\"\u003eMounting Type: Bolt-On\u003c\/li\u003e\n\u003cli data-section-id=\"qfdg24\" data-start=\"2634\" data-end=\"2675\"\u003eBreaker Type: Standard Thermal Magnetic\u003c\/li\u003e\n\u003cli data-section-id=\"pqobmh\" data-start=\"2676\" data-end=\"2726\"\u003eTrip Functions: Long-Time and Instantaneous (LI)\u003c\/li\u003e\n\u003cli data-section-id=\"mkyodu\" data-start=\"2727\" data-end=\"2754\"\u003eInterrupt Rating: 22 kAIC\u003c\/li\u003e\n\u003cli data-section-id=\"12p38x5\" data-start=\"2755\" data-end=\"2796\"\u003eWire Size: AWG 4–2\/0 Copper or Aluminum\u003c\/li\u003e\n\u003cli data-section-id=\"4bsicr\" data-start=\"2797\" data-end=\"2851\"\u003eCertifications: UL Listed, CSA Certified, HACR Rated\u003c\/li\u003e\n\u003cli data-section-id=\"tgtv9u\" data-start=\"2852\" data-end=\"2919\" data-is-last-node=\"\"\u003eApplication: Commercial and industrial branch circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Square D","offers":[{"title":"NEW","offer_id":48538043515129,"sku":"QOB280VH","price":183.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/7810\/7385\/files\/QOB280VH-All-New-1_ff5bf520-335e-4c73-a502-6b36e2c511af_1.jpg?v=1781638489","url":"https:\/\/mycircuitbreakers.com\/products\/square-d-qob280vh-80a-2-pole-thermal-magnetic-circuit-breaker-bolt-on-mount-120-240v","provider":"My Circuit Breakers","version":"1.0","type":"link"}